Labview 2018 Matlab Node Download For Mac



Labview

  1. Labview For Mac Download
  2. Labview 2018 Matlab Node Download For Mac
  3. Angular Cli

Labview 2018 Matlab Node Download For Mac

Known Issues by Category

  • You can process scripts using LabVIEW MathScript in the LabVIEW MathScript Window or a MathScript Node. About LabVIEW MathScript RT Module. The LabVIEW MathScript Module adds textual math to the LabVIEW development environment with a native compiler for the.m files you have developed in MATLAB or GNU Octave software.
  • Because LabVIEW uses ActiveX technology to implement MATLAB script nodes, they are available only on Windows. Add this node to the block diagram and enter the script. You also can right-click the node border to import text into the node. Right-click the node border to add input and output terminals. Right-click a terminal to set its data type.

Matlab MATLAB ® is a high-level language and interactive environment for numerical computation, visualization, and programming. Using MATLAB, you can analyze data, develop algorithms, and create models and applications.

Labview 2018 Matlab Node Download For Mac

How to install office 2019. The following items are known issues in LabVIEW 2018 sorted by Category.

Labview For Mac Download

ActiveX and .NET
245359 Selecting a newer version of a .NET assembly does not reload assembly
355840 'Get Image' method is unreliable on .NET controls in LabVIEW (64-bit)
381128 The MonthCalendar .NET control automatically resizes to the incorrect size when the VI is run
410479 Grouping ActiveX containers removes inserted ActiveX objects
468139 .NET Callback Event VI keeps the Callback VI reserved even after calling a Close Reference VI is called
480386 ActiveX call to open PDF (Adobe Reader 11.0.07) results in LabVIEW crashing
493624 Change of .NET assembly version requires manual relink of static class methods/properties
493662 .NET Constructor Node cannot differentiate between functions with different enums at the same position
558774 Constructor node for FolderDialogBox from Windows.System.Forms (4.0.0) causes hang during execution
565884 When creating .NET assemblies in LabVIEW, 1-dimension arrays of doubles or strings are represented as 2-dimension arrays of rank 1
596788 The struct ErrorCluster from InteropAssembly throws case sensitivity error in Visual Basic
Analysis and Math
169840 Large matrix operations that utilize the Intel MKL on Linux may crash LabVIEW
388446 Eval Parsed Formula Node.vi returns incorrect results
408891 Getting an Entire Column of Data from a 2D Array in the MATLAB® Script Node Returns Only 1 Element
Building and Distributing LabVIEW Applications
51179 47B12U5U Error 6 occurred at Create Folder in Create Directory Recursive.vi when building an application (EXE), shared library (DLL), source distribution or web service
208364 LabVIEW built installers created on a 32-bit machine will not install most drivers when run on a 64-bit machine
227609 Statically linking a LabVIEW built DLL in a C++ project results in error 998 if the DLL is not added to the Delay Loaded DLLs list
282737 Applications with Chinese characters in the executable name will throw fatal error on English Windows 7
320485 User Events Created from Objects Cause Broken Packed Library VIs
351741 Panes 'Top' pixel coordinates will vary when Windows 'Aero' is enabled/disabled
347272 Executables built (without SSE2) in LV 2011 on an Intel Core Duo machine throw Error 57 when run on a machine with an AMD Athlon 3200+ processor.
401421 Updates to Global Variables Not Visible when Remote Debugging a LabVIEW Built Stand-Alone Application
590224 In some cases, using an XControl in a PPL can cause LabVIEW to hang
596788 The struct ErrorCluster from InteropAssembly throws case sensitivity error in Visual Basic
599746 When building a web service into an EXE and making an installer, some software dependencies are not automatically selected as additional installers
606191 Building a .NET Interop Assembly with an array of classes as an output fails
607411 When using a LabVIEW-built .NET Interop Assembly in an ASP .NET application, the first call to the assembly will return a NullReferenceException
634287 Incorrect behavior when creating a .NET Interop Assembly with typedefs
652898 LabVIEW crashes when attempting to open detailed help for an EXE
674079 Packed Libraries that have debugging enabled and use XNodes load slowly
674968 LabVIEW does not automatically detect the LabWindows/CVI Runtime installer as a required dependency when building an installer from an EXE that requires the LabWindows/CVI Runtime
684847 Nested PPL VIs cannot be found when debugging built executable
Compatibility
529278 MATLAB Script Node can output different data in LabVIEW 32-bit vs. 64-bit
Controls and Indicators
219819 Center justified tables display improperly when overlapping with the front panel origin
51311 477DKPBQ LabVIEW does not maintain child-only item setting when dragging an item within a tree
208088 Updating the Labels of a Cluster Written to a Chart Does Not Update the Cluster Used for Chart History
185890 Text on a VI can be mutated to appear as Unicode
176848 Picture Control Stops Updating After Setting Properties to Default.
236377 Dropping XControl from public library breaks XControl
248914 Changing the order of controls or deleting controls in a type def cluster can change references
250588 Warning Generated in a Method or Property of an XControl Appears as an Error in the Top Level VI
290105 Text Labels in Silver Control are not in silver style
314082 Listbox Control With Transparent Cell Background Does not Grey Disabled Item
239719 Property page doesn't update when Adapt to Source is coerced to off
364845 Streaming data to a Digital Display Chart data occasionally incorrectly displays zero even when the data is non-zero
367249 It is not possible to customize the Run-Time Shortcut menu of a 3D Graph
398998 3D Surface Axis Labes not Visible when Dialog Font Changed
399068 Double Numeric Slide can not be Set to 0 when it has Defined Limits with Mouse
407614 Control.Delete Method Crashes LabVIEW When Used on Grouped Pictures and Free Labels
420965 Adding a tooltip for a tab control after configuring the tab to show text and image can cause the tooltip to appear in the wrong position
422507 Entering an integer into a numeric control that has a time display format does not update the control
428515 On Scientific Linux 6.3 with updated Mesa Drivers, 3D Picture Controls display an inverted image
425313 Selecting the option to hide grid lines when using Export Simplified Image with a waveform graph will not hide all grid lines when using multiple axis
432182 Custom labels on a 3D bar chart do not display properly in a 2D view
428914 The Y-Axis of a Mixed Signal Graph will not correctly scale when the graph is set to 'Scale Object with Pane' and the user decreases the size of the VI Front Panel.
433596 The 3D Surface Plot does not draw correctly when the input data is an array of the same value
485336 Deleting a second y-axis on a waveform graph with a cursor crashes LabVIEW
507856 Replacing an Intensity Graph with z-axis autoscaling enabled with a Waveform Graph or XY Graph causes LabVIEW to crash
544257 Inplace issue can occur when using LabVIEW 32-bit on a 64-bit operating system.
584455 Certain Silver Controls appear differently on Front Panel versus Print Output
585867 LabVIEW 64-bit can crash while closing a VI containing certain ActiveX containers
317117 3D Surface Graph incorrectly blends colors when interpolating
624802 Setting binding properties of a control within a preallocated clone subVI or XControl sets the property for all instances of the subVI or XControl
631762 Using Export data to Excel on a Waveform Chart that contains an empty waveform can cause LabVIEW to crash
633309 Waveform graphs can resize at runtime
640243 XY graph pointers do not copy correctly using Copy Data operation
339230 Newly created typedefs are not automatically added to library
678964 Nested XControls require recompile when built into Packed Project Libraries
670209 Changing XControl state may lock XControl permanently
DataSocket
624802 Setting binding properties of a control within a preallocated clone subVI or XControl sets the property for all instances of the subVI or XControl
Example Programs
542436 Block Diagram Cleanup on the Receive Message.VI in Actor Framework can cause an access violation crash within LabVIEW.
External Code
153731 Unhandled Exception can occur if absolute path for system DLL used in CLFN
509876 Bundle by Name function can send wrong pointer into subVI with Call Library Function Node
634531 Template methods in a C++ DLL do not appear in the Function Name drop down list of the Call Library Function Node.
File I/O
47819 3N68LE00 2GB file size limit of datalog files
243468 Default Namespaces not supported in XML Parsing VIs
239631 Memory Growth with TDMS Write
437390 File Path control does not display 'Browse' dialog if Start Path is an invalid network path.
492341 LabVIEW TDMS Advanced Asynchronous Write does not return error when target disk is full.
504716 Advanced Asynchronous Write function does not return an error when target disk is full or removed
528963 File Dialog Express VI crashes when passed a null hex string as the pattern input
544623 LabVIEW 64-bit for Mac OS can improperly create special characters.
574329 Error 4 thrown in executable but not in development environment
602529 Open/Create/Replace File does not return an error when attempting to create a file name that is restricted by the OS
616849 LabVIEW files are saved without an extension after attempting to save with an invalid character
618568 Reference leaks with the Audio DataPlugin
629032 Wiring a 2D array with an empty string to the property names input of the TDMS Set Properties function causes data for that channel to be unreadable
640089 DETT reports a reference leak when using the Open Data Storage express VI and Close Data Storage express VI
641269 Interleaved TDMS Write with duplicate channel names fails to write data without returning an error
Functions, VIs, and Express VIs
39161 401FEQTL The device ID input of the Play Sound File VI does not work on Windows
48016 3P7CBB4Q Unsigned int32 loses value in formula node when you write to the most significant bit
50420 44CG88SN Update the Pulse Transition Measurement Express VI
120686 Write to LabVIEW Measurement Files (LVM) using Express VIs takes up a lot of memory
213279 Some nodes may crash or yield incorrect/inconsistent results when Inlined
227030 Wait on Notification from Multiple function has unexpected behavior when ignoring previous input.
235019 OpenSSL fatal error when LabVIEW exits
196607 DTbl Replace Subset VI behavior change between LabVIEW 8.6.1 and 2009
322914 Formula VI does not execute pow(x,y) function
289842 Get Variant Attribute VI returns wrong value if attribute not found
279373 SMTP has been updated to use port 587; LabVIEW makes use of legacy port 25
359662 Some dotted scripting property calls can crash LabVIEW if earlier properties error
202192 LabVIEW UDP broadcast is inconsistent across different OS's.
335576 Play Waveform Express VI gives error 4803 with Sample Rate 3125, 6250, 12.5K, 25K, 50K, 100K, 200K Hz
353261 Conditional Indexing Terminal on Parallel For Loop with Shift Registers Runs with 'Memory is Full Error'
381656 Adding or subtracting timestamps causes a conversion to double and precision loss
391784 Memory Lead when Sound VIs are Called Dynamically
392545 Timed Loop crashes LabVIEW after exiting
406311 VI.Control Value.Set will Crash LabVIEW When Value Non-Variant Data is Used for Value Parameter
407633 Set Cell Value Method Returns Error 1604
410904 Print.VI to Printer Method Always Prints Header in LabVIEW Built Applications
412979 Flatten to XML String does not properly escape single and double apostrophes in a string input (' and ')
390021 An inlined VI can not be placed on the block diagram of a VI with subroutine priority unless it also has subroutine priority
384591 A password protected VI accessing a password protected community scoped VI is broken if the VIs are set to separate compiled code from source code
442745 RF-RIO Instr Default Personality 5646R.lvproj's FPGA VI will hang on save.
467735 'Format into File' produces Error 1 when appending to a file that has a size of 4 GB
510218 Create Mask.vi does not work in conjunction with the Get Image Subset.vi in LabVIEW
515300 NamedBundler function in LV Scripting does not work properly when the reference is opened from a New VI function
525685 Error -2628 is returned when parsing an XML file with a Document Type Definition file
570754 Linear Fit produces NaN result if X input value is too large
521856 Rare LabVIEW crash when using 'Panel Close?' filtering event and 'Quit LabVIEW' function
552304 SMTP Client VI Example incorrectly converts some characters when placed in subject line
571353 XNode can cause Dirty Dot when no parameters are modified
603204 When using a cylindrical coordinate system on a 3D scatter plot, the color ramp legend does not reflect the displayed color gradient
607058 Flattening an EXT representation numeric to JSON causes loss of precision
613423 Registering for an event for multiple boolean controls can fail in specific configurations
617826 LabVIEW will not generate a Key Down event if the mouse is held down on a cell inside a table control
627783 Using TCP Open Connection with a Timeout of 0 can cause connection failures
640089 DETT reports a reference leak when using the Open Data Storage express VI and Close Data Storage express VI
634261 The Block Diagram.Get Image Scaled method displays subVIs as black rectangles if the image depth is less than 8.
654057 When using clusters with a reference to the same control to register for multiple events, LabVIEW does not properly handle all events.
655865 The VI Method Save.For Previous fails to maintain the status of the 'Separate compiled code from source file' attribute
656572 In some cases, some primitives may not properly display coercion dots when converting between integer representations
631422 Regenerate Channel Instances stop responding
677020 Channel wires do not update minor changes in data type
686273 Sound Output VIs can cause LabVIEW to freeze on Mac OS
I/O Servers
638070 LabVIEW crashes when calling the Children[] Property Node in a VI with reentrancy set to 'Shared clone reentrant execution.'
Installation and Activation
583670 If LabVIEW 2016 is installed, installers built in any version of LabVIEW will not work on Windows 7 RTM and older
LabVIEW Environment
105509 The 'do not save automatic changes' setting does not affect libraries
95055 Save for previous fails if file path is too long
256141 Windows 7 often shows '(Not Responding)' and will bring other windows to the front during expensive operations
238713 3D Picture Controls can display transparently or crash LabVIEW on certain graphics cards
257194 Connector pane of a VI can change from LabVIEW 2009 to LabVIEW 2011
244551 Editing large strict type definitions can take a long time to update
369142 Front Panels may stop updating with 3+ monitors with Windows Aero enabled
305978 Save As Duplicate with Include All Dependencies makes a Copy of the instr.lib Folder.
408790 Palette Editor Cannot Add LabVIEW Classes
430758 It is not possible to save a VI with the name of another VI in memory, even if they are in different libraries
478232 In certain cases, LabVIEW may incorrectly crisscross wires during loop creation
470218 LabVIEW (64-bit) for Mac, does not show the login prompt for Revision History when starting LabVIEW
420582 Typing Obtain in Quick Drop populates with an unexpected selection
584837 Mass compiling a project from project explorer in certain cases can cause LabVIEW to hang.
457854 Aborting a VI can leave VIs targeted by a Call By Reference node reserved permanently
542436 Block Diagram Cleanup on the Receive Message.VI in Actor Framework can cause an access violation crash within LabVIEW.
544257 Inplace issue can occur when using LabVIEW 32-bit on a 64-bit operating system.
558891 In some scenarios, LabVIEW Menu positions within a VI or project are offset in Windows 10
578085 Saving a very large VI in LabVIEW 2015 and later can take longer than in previous versions
639524 Changing font to Application font can shrink constants inside of structures
678334 Changing the keyboard shortcut of the Bookmark Manager to Ctrl+Shift+3 does not launch the Bookmark Manager when the shortcut is pressed.
LabVIEW Object Oriented Programming
52027 4A4GRP00 Cannot use the 'New>>VI for Override..' dialog to create override of password-protected VI unless you have the password
103315 Creating a circular link between an Xcontrol and a LVClass can crash LabVIEW.
245148 Class Properties dialog sometimes throws timeout error 123 when opening and must be restarted
284936 Breaking one Override VI in LVOOP shows all siblings as broken but does not explain why
233061 4AQA5L00 LabVIEW crashes after working with Simulation Subsystem using a LabVIEW Class
356656 Crash when compiling VIs that call into a certain class based VI hierarchies
391455 Applying an icon to LabVIEW class overwrites the icons of its methods
410360 LabVIEW Classes Become Corrupt When Multiple Files With Same File Name are Added to the Class
461969 When using a class containing a DAQmx Physical Channel control, it will not properly load that information from an XML file.
432523 Reordering elements of a cluster within the private data of a class can break VIs that reference the class
633648 LabVIEW crashes when replacing the Actor Framework library with a packed library
686080 Replacing ActorFramework.lvlib with a packed project library causes LabVIEW crash
686379 Objects flattened to XML may revert data to default value
LabVIEW Project
163371 'Save As:Copy' on a nested library breaks member VIs if use option to add copied library to owner library
232348 Changes to a library item's access scope sometimes do not update broken callers.
377385 Error 1390 on Dynamic VI Call to Friend Library
257735 Class VIs that call shared variables in a library in an auto-populating folder will not be loaded
408391 Non-printable Characters in the Description of Will Corrupt LabVIEW Classes and Libraries
430758 It is not possible to save a VI with the name of another VI in memory, even if they are in different libraries
339230 Newly created typedefs are not automatically added to library
MathScript
469268 Formula Node and MathScript Node variable labels can shift to become misalligned
Miscellaneous
389041 Error -314250 from Create Network Stream Writer Endpoint
403727 Repeated Dynamic Calls to VI in Packed Project Library Can Cause Error in VI Call
415924 Double precision numeric constants set to 'bar' units sometimes use Pa units
NI Services
364338 'Error while retrieving database: Forbidden' connecting to a RT target via the web configuration.
Operating System Specific
351506 [Mac] Test Device option on Play Waveform Express VI Configuration page doesn't output test tone
403182 Sound Output.vi Does Not Support more than 2 Audio Channels on Windows 7
405271 Boolean Mechanical Actions Don't Work as Expected on Windows 8 Touch Screen
462021 In LabVIEW for Mac, filtered menu tracking is not cancelled until the event's case finishes executing
634015 Certain operations will not let the System Exec VI return on Windows 10
686923 Bring to Front Invoke Node may not bring window to front
Performance
390021 An inlined VI can not be placed on the block diagram of a VI with subroutine priority unless it also has subroutine priority
Remote Panels
181687 Web publishing tool fails without error
136677 Remote panels do not work if Internet Explorer is embedded in an ActiveX or .NET Container
251105 S&V XControls built as Remote Panel crashes LabVIEW.
625718 The Web Publishing Tool has incompatibility issues with Internet Explorer 11
Shared Variables
141699 NI Distributed System Manager does not show deployed libraries if they contain non-Latin characters.
128059 Shared variable bindings in the same library are not updated properly when copying/renaming the library
168005 Dynamic Variable API Does Not Support I/O Servers that Use Ranges
186808 Shared Variable library on PC is undeployed if the a V in the same project is programmatically deployed to a Real-Time target
284289 Source distributions with block diagrams removed prevents the use of static Shared Variable nodes.
294285 Type Defined Shared Variable not found in Executable
257735 Class VIs that call shared variables in a library in an auto-populating folder will not be loaded
394454 Data Binding: Path property can change bindings in other VI clones
458973 Writing a negative number to single point float Network Shared Variables through the OPC I/O Server fails.
614154 Renaming a shared variable with a special character in its name (ö/ü/ä/ß) fails when the project is reopened
624802 Setting binding properties of a control within a preallocated clone subVI or XControl sets the property for all instances of the subVI or XControl
647354 Opening a new shared variable connection can block reading from other connected variables
Source Code Control
229641 Hang can occur when deploying RT project that has not been check out of VSS
676013 LVMerge returns error 53 when the VI has a dependency on an XControl
Toolkit - Report Generation
188911 Control image alignment incorrect when 'new report page' VI is used
Toolkit - Unit Test Framework
635510 Adding a diagram disable structure to a VI can cause the reported code coverage to be 100%
Upgrade - Behavior Change
51185 47FGSQCS Cannot save VI as the same name as missing library member VI
119444 Multi-column listbox format lost on upgrade
198717 Unflatten From XML fails for cluster and arrays that consist of variants
218083 VIs with errors may show additional errors for code in disabled frames of Conditional Disable Structure
Web Server/Web Services
236817 NI-Auth does not work with Firefox
401078 Opening any non-VI dialog, such browse for files or one button dialog, may block web service requests from executing.
570102 Calling the 'Web Server: Server Active' property causes a small memory leak.
576990 Assembly created by Web Service Importer from WSDL throws error 1172
599746 When building a web service into an EXE and making an installer, some software dependencies are not automatically selected as additional installers
688771 Cannot add CA-signed certificates to LabVIEW Web Services

Labview 2018 Matlab Node Download For Mac

 

ID Known Issue
ActiveX and .NET
245359
Return
Selecting a newer version of a .NET assembly does not reload assembly
Changing a constructor from an old version of a .NET assembly to a newer version at edit time does not cause the new assembly to be loaded and consequently none of the new functionality is available.
Workaround: 1. Remove the old assembly so the .NET Runtime is not able to find it. It will then return the updated version to LabVIEW.
2. Load the new assembly in a blank VI before opening your existing VI. This will load the new version into memory prior to you requesting the older version.
Reported Version: 2010 32-bit Resolved Version: N/A Added: 08/03/2012
355840
Return
'Get Image' method is unreliable on .NET controls in LabVIEW (64-bit)
Calling the 'Get Image' method on a .NET control works correctly on 32-bit versions of LabVIEW, but will fail to return an image intermittently when LabVIEW (64-bit).
Workaround: n/a
Reported Version: 2011 64-bit Resolved Version: N/A Added: 08/03/2012
381128
Return
The MonthCalendar .NET control automatically resizes to the incorrect size when the VI is run
N/A
Workaround: At the beginning of the code write to the Container Bounds property node 'ContBounds' for the .NET container. While the code is running the calendar will have the right size
Reported Version: 2012 Resolved Version: N/A Added: 02/01/2013
410479
Return
Grouping ActiveX containers removes inserted ActiveX objects
When populated ActiveX containers are grouped with other front panel objects, the inserted ActiveX object will be removed.
Workaround: Re-insert the ActiveX object after it has been grouped with another object, or group a blank ActiveX container, then insert the object.
Reported Version: 2012 SP1 Resolved Version: N/A Added: 08/02/2013
468139
Return
.NET Callback Event VI keeps the Callback VI reserved even after calling a Close Reference VI is called
For example, when running the 'Passing data to a .NET Event Callback.vi' example, after stopping the main example VI, the 'Callback - EventHappened.vi' is still reserved.
Workaround: Call GC.Collect() from an invoke node or in a separate VI to un-reserve the callback VI.
Reported Version: 2013 SP1 Resolved Version: N/A Added: 05/07/2014
480386
Return
ActiveX call to open PDF (Adobe Reader 11.0.07) results in LabVIEW crashing
More information at https://forums.adobe.com/message/6396203#6396203
Workaround: Downgrade to an earlier versions of Adobe Reader (11.0.6 and earlier)
Reported Version: 2013 Resolved Version: N/A Added: 07/31/2014
493624
Return
Change of .NET assembly version requires manual relink of static class methods/properties
A version change to a .NET assembly (the only change) breaks the reference connection of methods/properties of static classes. When starting LV with the new assembly version, the version change warning is shown but the run arrow is broken. A manual relink of the properties/methods is required.
Workaround: N/A
Reported Version: 2013 SP1 Resolved Version: N/A Added: 06/17/2015
493662
Return
.NET Constructor Node cannot differentiate between functions with different enums at the same position
N/A
Workaround: Create a wrapper assembly to call from LabVIEW
Reported Version: 2014 Resolved Version: N/A Added: 06/17/2015
558774
Return
Constructor node for FolderDialogBox from Windows.System.Forms (4.0.0) causes hang during execution
In recent versions of LabVIEW, placing a constructor for a FolderDialogBox object from Windows.System.Forms (4.0.0) will work successfully, but the containing VI will hang during execution.
Workaround: Do not use FolderDialogBox objects.
Reported Version: 2012 SP1 Resolved Version: N/A Added: 08/08/2016
565884
Return
When creating .NET assemblies in LabVIEW, 1-dimension arrays of doubles or strings are represented as 2-dimension arrays of rank 1
When creating .NET assemblies in LabVIEW, 1-dimension arrays of doubles or strings are represented as 2-dimension arrays of rank 1. This can create an issue when the assembly is used in Visual Studio 2015 which will not accept 2-dimensional arrays of rank 1.
Workaround: Pass a 2D array in LabVIEW instead of a 1D array.
Reported Version: 2013 SP1 Resolved Version: N/A Added: 08/08/2016
596788
Return
The struct ErrorCluster from InteropAssembly throws case sensitivity error in Visual Basic
The user gets the following error when using the struct ErrorCluster in Visual Basic: 'Status' is ambiguous because multiple kinds of members with this names exist in structure 'ErrorCluster'.
The struct NationalInstruments.LabVIEW.Interop.ErrorCluster defined in the DLL NationalInstruments.LabVIEW.Interop.dll has the following variable definition:
Public code As Integer
Public source As String
Public status As Boolean
Public Sub New(statusIn As Boolean, errorCode As Integer, errorMessage As String)
Public ReadOnly Property Code As Integer
Public ReadOnly Property Source As String
Public ReadOnly Property Status As Boolean
The first three members have the same name of the last three aside from the capitalization of the first letter. Although MSIL is case-sensitive, VB is case-insensitive, which is therefore causing the error.
Workaround: 1. Use the generic .NET Exception, which will have the same information as the ErrorCluster.
2. Build a wrapper in C#, then use that in VB.NET
Reported Version: 2015 SP1 Resolved Version: N/A Added: 05/22/2017
Analysis and Math
169840
Return
Large matrix operations that utilize the Intel MKL on Linux may crash LabVIEW
When one or more matrix operations consumes most of the system resources, the Intel MKL library produces an unhandled exception that results in a LabVIEW application crashing.
This Intel library is used to accelerate fundamental linear algebra operations performed under Linux operating systems. This issue has been reproduced outside the LabVIEW execution environment and a bug report has been submitted to Intel.
Because the crash is tied to system resources, it can manifest itself in many ways. For example, we have reliably reproduced the problem by:
1. Decomposing a large matrix into multiple large matrices.
Specific example: Computing the singular value decomposition (SVD) of a 2500-by-2500 matrix on a system with 256M RAM.
2. Simultaneously computing multiple matrix operations using relatively small matrices.
Specific example: Computing 30 matrix expressions using 300 x 300 matrices on a system with 512 MB RAM.
Workaround: If you have identified one or more matrix operations in your application that exhibit this behavior, you have multiple options to avoid crashing.
1. Serialize the matrix operations so that they are not consuming resources in parallel.
2. Replace affected matrix arithmetic functions using Basic Linear Algebra Subroutine (BLAS)functions found on the BLAS palette.
3. Structure your application so that these operations are not competing with other functions for system resources.
Reported Version: 2009 32-bit Resolved Version: N/A Added: 11/10/2009
388446
Return
Eval Parsed Formula Node.vi returns incorrect results
Incorrect results are possible if preceding Parse Formula Node.vi contains too many C-style comments.
Workaround: Reduce the amount of comments used in formula input to Parse Formula Node.vi
Reported Version: 2012 Resolved Version: N/A Added: 08/02/2013
408891
Return
Getting an Entire Column of Data from a 2D Array in the MATLAB® Script Node Returns Only 1 Element
In the context of the MATLAB® Script Node, attempting to return an entire column of data from an array using a command like 'column1 = array2D(:,1);' returns only a single element. This same operation on a row 'row1 = array2D(1,:);' , returns the entire row successfully.
Workaround: Transpose the array, and get the data in it's context as a row.
Reported Version: 2012 Resolved Version: N/A Added: 10/16/2013
Building and Distributing LabVIEW Applications
51179
47B12U5U
Return
Error 6 occurred at Create Folder in Create Directory Recursive.vi when building an application (EXE), shared library (DLL), source distribution or web service
When building a Build Specification, the build process fails with Error 6 at Create Folder in Create Directory Recursive.vi. This usually happens if the path one of the files generated by the build (temporarily during the build process or as part of the output) is too long. The operating system requires paths for files to be less than 255 characters.
Workaround: 1. Use a shorter path for your build destination (i.e. c:build) and if necessary copy the output to the final location you need.
2. A. For application (EXE) and shared library (DLL) build specifications, place a checkmark in the Use LabVIEW 8.x file layout checkbox on the Advanced page of the Properties dialog box.
2. B. For source distribution or web service build specifications, uncheck the Preserve disk hierarchy checkbox on the problem Destination on the Destinations page of the Properties dialog box.
Reported Version: 8.2.1 Resolved Version: N/A Added: 10/06/2008
208364
Return
LabVIEW built installers created on a 32-bit machine will not install most drivers when run on a 64-bit machine
If you build an installer using LabVIEW on a 32-bit machine that contains National Instruments drivers, the corresponding drivers will not be installed if the installer is run on a 64-bit machine. Drivers such as NI-DAQ, NI-Sync etc. are affected by this issue. Installation on 32-bit machines are not affected by this bug.
Workaround: On the deployment 64-bit machine, download and install the missing drivers from the ni.com Drivers and Updates page
Reported Version: 8.5 Resolved Version: N/A Added: 02/16/2010
227609
Return
Statically linking a LabVIEW built DLL in a C++ project results in error 998 if the DLL is not added to the Delay Loaded DLLs list
For more information see this article
Workaround: Go to the Project Property Pages, Configuration Properties»Linker»Input and add the name of your DLL to the Delay Loaded DLLs list.
Reported Version: 7.1.1 Resolved Version: N/A Added: 06/16/2010
282737
Return
Applications with Chinese characters in the executable name will throw fatal error on English Windows 7
N/A
Workaround: Use a different name for the executable.
Reported Version: 2010 32-bit Resolved Version: N/A Added: 08/02/2011
320485
Return
User Events Created from Objects Cause Broken Packed Library VIs
If you are using an object as a user event, it works fine while in the LabVIEW environment. However, when compiled into a packed library, the user event refnum has a broken wire.
Workaround: N/A
Reported Version: 2010 SP1 32-bit Resolved Version: N/A Added: 08/02/2011
351741
Return
Panes 'Top' pixel coordinates will vary when Windows 'Aero' is enabled/disabled
If the Windows Vista/7 option to 'Use visual styles on windows and buttons' is enabled, a VI property node for Front Panel Window:Panel Bounds will return a different 'Top' value.
Workaround: If you are calculating the position of elements within your VI based on this value, check the deployed OS, and subtract an offset value.
Reported Version: 2011 32-bit Resolved Version: N/A Added: 05/07/2012
347272
Return
Executables built (without SSE2) in LV 2011 on an Intel Core Duo machine throw Error 57 when run on a machine with an AMD Athlon 3200+ processor.
n/a
Workaround: Build the executable on the Athlon 3200+ computer.
Reported Version: 2011 32-bit Resolved Version: N/A Added: 08/03/2012
401421
Return
Updates to Global Variables Not Visible when Remote Debugging a LabVIEW Built Stand-Alone Application
If the updates occured before connecting to the Remote Application with the debugger, the updates won't be visible. Updates to the Global Variable after connection with the debugger is establish will be visible.
Workaround: Change the build specification for the stand-alone application to wait for debugger on launch, so no Global Variable updates can happen until a debug session is started.
Reported Version: 2012 SP1 Resolved Version: N/A Added: 08/02/2013
590224
Return
In some cases, using an XControl in a PPL can cause LabVIEW to hang
If you build an XControl into a PPL and include the XControl on the front panel of a VI that is also built into the PPL, the VI can hang in some cases.
Workaround: N/A
Reported Version: 2015 SP1 Resolved Version: N/A Added: 05/22/2017
596788
Return
The struct ErrorCluster from InteropAssembly throws case sensitivity error in Visual Basic
The user gets the following error when using the struct ErrorCluster in Visual Basic: 'Status' is ambiguous because multiple kinds of members with this names exist in structure 'ErrorCluster'.
The struct NationalInstruments.LabVIEW.Interop.ErrorCluster defined in the DLL NationalInstruments.LabVIEW.Interop.dll has the following variable definition:
Public code As Integer
Public source As String
Public status As Boolean
Public Sub New(statusIn As Boolean, errorCode As Integer, errorMessage As String)
Public ReadOnly Property Code As Integer
Public ReadOnly Property Source As String
Public ReadOnly Property Status As Boolean
The first three members have the same name of the last three aside from the capitalization of the first letter. Although MSIL is case-sensitive, VB is case-insensitive, which is therefore causing the error.
Workaround: 1. Use the generic .NET Exception, which will have the same information as the ErrorCluster.
2. Build a wrapper in C#, then use that in VB.NET
Reported Version: 2015 SP1 Resolved Version: N/A Added: 05/22/2017
599746
Return
When building a web service into an EXE and making an installer, some software dependencies are not automatically selected as additional installers
If you build a web service into an EXE that has method VIs with software dependencies, such as the use of a hardware driver, only VIs with dependencies that are included as Startup VIs for the web service will be automatically selected as additional installers. Any method VI that is not a Startup VI will not have its software dependencies automatically selected.
Workaround: Build the web service into the installer rather than the EXE or manually include the required software dependencies
Reported Version: 2015 SP1 Resolved Version: N/A Added: 05/22/2017
606191
Return
Building a .NET Interop Assembly with an array of classes as an output fails
When an exported VI has an array of classes as an output, attempting to build the .NET Interop Assembly results in error 1172.
Workaround: Extract the data from the classes then bundle and output the data as an array of clusters
Reported Version: 2015 SP1 Resolved Version: N/A Added: 05/22/2017
607411
Return
When using a LabVIEW-built .NET Interop Assembly in an ASP .NET application, the first call to the assembly will return a NullReferenceException
N/A
Workaround: The exception only occurs on the first call to the assembly, so using a try-catch block to handle the exception will allow subsequent calls to behave normally.
Reported Version: 2015 SP1 Resolved Version: N/A Added: 05/22/2017
634287
Return
Incorrect behavior when creating a .NET Interop Assembly with typedefs
When you have multiple different typedefs with identical definitions (i.e, multiple numeric typedefs), only one of them is exported to a .NET typedef.
Workaround: N/A
Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017
652898
Return
LabVIEW crashes when attempting to open detailed help for an EXE
If the Help path property of a VI points to a PDF file, LabVIEW will crash when trying to open the detailed help of the EXE
Workaround: N/A
Reported Version: 2015 SP1 Resolved Version: N/A Added: 01/23/2018
674079
Return
Packed Libraries that have debugging enabled and use XNodes load slowly
Workaround: N/A
Reported Version: 2013 SP1 Resolved Version: N/A Added: 01/23/2018
674968
Return
LabVIEW does not automatically detect the LabWindows/CVI Runtime installer as a required dependency when building an installer from an EXE that requires the LabWindows/CVI Runtime
Workaround: Manually include the LabWindows/CVI Runtime
Reported Version: 2017 Resolved Version: N/A Added: 01/23/2018
684847
Return
Nested PPL VIs cannot be found when debugging built executable
PPLs containing VIs from other PPLs can successfully build into an executable. If a debuggable version of the executable is built, LabVIEW will show the VIs as not found. This prevents debugging from seeing the block diagram for the nested VIs. They will continue to run as programmed.
Workaround: N/A
Reported Version: 2016 Resolved Version: N/A Added: 03/14/2018
Compatibility
529278
Return
MATLAB Script Node can output different data in LabVIEW 32-bit vs. 64-bit
N/A
Workaround: Use LabVIEW 32-bit for MATLAB Script Nodes
Reported Version: 2014 SP1 Resolved Version: N/A Added: 08/08/2016
Controls and Indicators
219819
Return
Center justified tables display improperly when overlapping with the front panel origin
When you add a table control to the front panel so that it overlaps with the vertical origin of the front panel, LabVIEW displays center justified columns off center when you type text. The cells appear to float or move horizontally until aligned with the vertical origin. Formerly tracked as 50061 and 42NAR8SA
Workaround: Move the table away from the front panel's vertical origin.
Reported Version: 8.0.1 Resolved Version: N/A Added: 09/01/2007
51311
477DKPBQ
Return
LabVIEW does not maintain child-only item setting when dragging an item within a tree
If you have a tree item with the child-only setting, and then drag it within the tree, LabVIEW loses the child-only setting.
Workaround: Use tree events to (1) get the child-only flag setting when the user begins a drag, and (2) reset the child-only flag after completing a drop.
Reported Version: 8.2.1 Resolved Version: N/A Added: 09/01/2007
208088
Return
Updating the Labels of a Cluster Written to a Chart Does Not Update the Cluster Used for Chart History
Changing the Label of elements in a cluster written to the Waveform Chart does not update the label of the cluster when read from the Waveform Chart Data History Property.
Workaround: Temporarily wire up a completely different data type to the Waveform chart indicator and then rewire the original cluster. The changes will now propagate to the Chart History.
Reported Version: 2009 32-bit Resolved Version: N/A Added: 03/09/2010
185890
Return
Text on a VI can be mutated to appear as Unicode
After building a project into an executable, various text for controls and indicators changes languages. It appears that the text was interpreted as Unicode.
We have not been able to reproduce this in house to find a definite cause. Because of this we will leave this CAR open even though we have created code to recover from the corruption if it happens.
Previously tracked as CAR 179683
Workaround: Upgrade the VI to LabVIEW 2011. In 2011 we put in code to only view text on VIs as unicode if the UseUnicode=True is in the LabVIEW .ini file. Previously this would only switch on the ability to change something to unicode.
When the VI is upgraded to 2011 it should be saved and then saved for previous to return it to the original version. More details are in this article
Reported Version: 8.6.1 Resolved Version: N/A Added: 07/23/2010
176848
Return
Picture Control Stops Updating After Setting Properties to Default.
Once the picture control's values have reinitialized to default by selecting Data Operations»Reinitialize to Default or programmatically using the method Reinitialize to Default, the mouse position property node stops updating.
Workaround: Replace the picture control with a new one from the palette.
Reported Version: 8.6.1 Resolved Version: N/A Added: 09/24/2010
236377
Return
Dropping XControl from public library breaks XControl
When adding an X control from a public library into the controls palette, it become broken when dropped down to the front panel from the controls palette.
Workaround: Include a merge VI in the functions palette
Reported Version: 2009 32-bit Resolved Version: N/A Added: 10/01/2010
248914
Return
Changing the order of controls or deleting controls in a type def cluster can change references
When you create a reference for a control in a type defined cluster LabVIEW uses the cluster order to determine what control the reference is referring to. Say you have a type defined cluster with elements A, B, C and D with cluster order 1,2,3 and 4 respectively. On the block diagram of a VI you have control references to each of the controls. If you open the type def and delete control C the block diagram of the VI will only contain 3 references. Moreover, the reference that used to be for control C will now reference control D. This is because the control is based on cluster order
Workaround: N/A
Reported Version: 7.1.1 Resolved Version: N/A Added: 10/01/2010
250588
Return
Warning Generated in a Method or Property of an XControl Appears as an Error in the Top Level VI
If you create a method or a property in an Xcontrol in which you have implemented code to generate a warning it is transformed into an error in the calling VI.
Workaround: In the VI look for specific error and transform back to a warning
Reported Version: 8.5.1 Resolved Version: N/A Added: 11/02/2010
290105
Return
Text Labels in Silver Control are not in silver style
Workaround: N/A
Reported Version: 2011 32-bit Resolved Version: N/A Added: 04/05/2011
314082
Return
Listbox Control With Transparent Cell Background Does not Grey Disabled Item
n/a
Workaround: Make the background color of the cells match the background of the panel, instead of making them transparent.
Reported Version: 2011 32-bit Resolved Version: N/A Added: 09/07/2011
239719
Return
Property page doesn't update when Adapt to Source is coerced to off
If you have a FXP constant with Adapt to Entered Data set and make any modifications to the display format, the resulting constant will not be set to adapt. The property page will not reflect this change before it is closed.
Workaround: Always double-check condition of Adapt To Entered Data.
Reported Version: 2010 Resolved Version: N/A Added: 08/03/2012
364845
Return
Streaming data to a Digital Display Chart data occasionally incorrectly displays zero even when the data is non-zero
N/A
Workaround: N/A
Reported Version: 2012 Resolved Version: N/A Added: 01/29/2013
367249
Return
It is not possible to customize the Run-Time Shortcut menu of a 3D Graph
N/A
Workaround: N/A
Reported Version: 2012 Resolved Version: N/A Added: 01/29/2013
398998
Return
3D Surface Axis Labes not Visible when Dialog Font Changed
Some fonts cause the Axis Labels to be visible on 3D Surface controls when the Dialog Font is changed from default. For example MS Sans Serif causes the issue.
Workaround: Use a Dialog font that doesn't cause the issue.
Reported Version: 2012 Resolved Version: N/A Added: 08/02/2013
399068
Return
Double Numeric Slide can not be Set to 0 when it has Defined Limits with Mouse
A user can not slide a Double Numeric Slide to 0 when it has defined increment, maximum, and minimum properties. Instead of 0, a value very close to 0 will be entered ie: 5.55112E-16.
Workaround: Do not set both defined maximum and minimum for the slide. Instead, change one of them to Inf or -Inf. Also a value of 0 can be entered into the digital slide.
Reported Version: 2012 Resolved Version: N/A Added: 08/02/2013
407614
Return
Control.Delete Method Crashes LabVIEW When Used on Grouped Pictures and Free Labels
LabVIEW will crash when VI scripting method Control.Delete is invoked on pictures or Free Labels that are grouped on the front panel.
Workaround: N/A
Reported Version: 2012 SP1 Resolved Version: N/A Added: 08/02/2013
420965
Return
Adding a tooltip for a tab control after configuring the tab to show text and image can cause the tooltip to appear in the wrong position
If you configure a tab control for text-image content, and then add an image and change the tooltip, the tooltip will appear far away from the tab control.
Workaround: View the tooltip after adding the image and before changing the default tooltip
Reported Version: 2012 SP1 Resolved Version: N/A Added: 10/14/2013
422507
Return
Entering an integer into a numeric control that has a time display format does not update the control
Double clicking inside a time display numeric control and typing a new value does not update to the new value, and the control reverts to its original value. This happens for controls with a display format of either %t or the default Relative Time format.
Workaround: If the display format is %t, enter values with a decimal point after the number (as a double)
If the display format is the default Relative Time, single click on the hour or minute fields and update individually or enter the value in the format HH:MM with the colon to successfully update
Reported Version: 2013 Resolved Version: N/A Added: 10/23/2013
428515
Return
On Scientific Linux 6.3 with updated Mesa Drivers, 3D Picture Controls display an inverted image
N/A
Workaround: Downgrade the Mesa drivers or manually invert the image.
If your 3rd-Party Mesa driver version is between 7.11 and 9.2.1, you need to add the LabVIEW INI token 'Invert3DPictImage=True'. Driver version 7.11 and earlier, and version 9.2.1 and later, do not need the INI token.
Reported Version: 2013 Resolved Version: N/A Added: 10/23/2013
425313
Return
Selecting the option to hide grid lines when using Export Simplified Image with a waveform graph will not hide all grid lines when using multiple axis
When using the waveform graph right-click option to Export Simplified Image with the option to hide grid lines, some of the grid lines will still be visible if there are multiple axis
Workaround: Disable the grid of the additional axis through the scale tab of the graph properties
Reported Version: 2013 Resolved Version: N/A Added: 03/11/2014
432182
Return
Custom labels on a 3D bar chart do not display properly in a 2D view
Custom labels on a 3D bar chart will revert to a numeric value when viewed in a 2D Projection
Workaround: N/A
Reported Version: 2013 Resolved Version: N/A Added: 03/14/2014
428914
Return
The Y-Axis of a Mixed Signal Graph will not correctly scale when the graph is set to 'Scale Object with Pane' and the user decreases the size of the VI Front Panel.
Increasing the size of the pane will result in the graph growing and scaling its axes correctly, but decreasing the size of the pane will only shrink the graph without scaling the Y-Axis. The Y-Axis will now have a scroll bar due to not scaling.
Workaround: Use the 'Plot Area' Property Node to shrink the graph to appropriate size.
Reported Version: 2013 Resolved Version: N/A Added: 03/31/2014
433596
Return
The 3D Surface Plot does not draw correctly when the input data is an array of the same value
The plot is completely blank if the array contains only the same value. Changing one value correctly draws the 3D Surface Plot
Workaround: Manually or programmatically toggle the Z-Axis range, or turn off Auto Scaling on Z-Axis, and the plot will appear
Reported Version: 2013 Resolved Version: N/A Added: 03/31/2014
485336
Return
Deleting a second y-axis on a waveform graph with a cursor crashes LabVIEW
When using a waveform graph indicator, it is possible to crash LabVIEW with an access violation error 0xC0000005 at EIP=0x00FE9E79 by creating two y-axis scales, creating a graph cursor, changing the cursor's associated y-axis, and then deleting the original y-axis scale.
Workaround: Remove the scale from the waveform graph, remove the unwanted y-axis scale, then recreate the cursor.
Reported Version: 2013 SP1 Resolved Version: N/A Added: 06/17/2015
507856
Return
Replacing an Intensity Graph with z-axis autoscaling enabled with a Waveform Graph or XY Graph causes LabVIEW to crash
N/A
Workaround: Delete the Intensity Graph and add a Waveform Graph or XY Graph rather than using the replace option.
Reported Version: 2014 Resolved Version: N/A Added: 06/17/2015
544257
Return
Inplace issue can occur when using LabVIEW 32-bit on a 64-bit operating system.
Running a VI that calls a subVI containing a Call Library Function Node to the kernel32.dll IsWow64Process can cause the returned value of the dll to be incorrect.
Workaround: Adding an 'Always Copy' dot before the control that is wired to the Front Panel Terminal within the subVI fixes the issue.
Reported Version: 2014 Resolved Version: N/A Added: 08/08/2016
584455
Return
Certain Silver Controls appear differently on Front Panel versus Print Output
When using the File >> Print option to print a Front Panel containing a Silver Boolean Control or Silver Meter Indicator, the printed version might not match up with the real values or style.
Workaround: Use other style controls
Reported Version: 2016 Resolved Version: N/A Added: 08/08/2016
585867
Return
LabVIEW 64-bit can crash while closing a VI containing certain ActiveX containers
Certain ActiveX containers such as Microsoft InkEdit Controls can cause complications when they are unloaded from memory in LabVIEW 64-bit, such as when the containing VI is closed.
Workaround: N/A
Reported Version: 2015 Resolved Version: N/A Added: 08/08/2016
317117
Return
3D Surface Graph incorrectly blends colors when interpolating
In certain situations when viewing a projection onto a 2D plane, the 3D Surface Graph can incorrectly blend colors instead of displaying them in a straight line.
Workaround: N/A
Reported Version: 2011 32-bit Resolved Version: N/A Added: 05/22/2017
624802
Return
Setting binding properties of a control within a preallocated clone subVI or XControl sets the property for all instances of the subVI or XControl
If the BindingPath property is set on a control within a preallocated clone subVI or XControl, all instances of the controls in the subVI or XControl update their BindingPath rather than the one where the property was set
Workaround: Create a unique SubVI or XControl for each instance
Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017
631762
Return
Using Export data to Excel on a Waveform Chart that contains an empty waveform can cause LabVIEW to crash
N/A
Workaround: Do not plot empty waveforms or add a data point that is out of range that can be manually removed from the Excel sheet
Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017
633309
Return
Waveform graphs can resize at runtime
For very large floating point numbers in a waveform graph, the control can permanently resize itself in an attempt to fit the large numbers in the axis label
Workaround: Use Automatic or Scientific as the format type for the Y Axis with large floating point numbers
Reported Version: 2017 Resolved Version: N/A Added: 05/22/2017
640243
Return
XY graph pointers do not copy correctly using Copy Data operation
When a graph annotation is displayed on an XY graph and the user copies the data using Data Operations>Copy Data, the image that is pasted does not properly display the pointers.
Workaround: Use a waveform graph instead of an XY graph when possible
Reported Version: 2012 SP1 Resolved Version: N/A Added: 05/22/2017
339230
Return
Newly created typedefs are not automatically added to library
When creating a subVI from a VI contained within a library, the subVI is added to the caller VI's library. When creating a typedef from a control in the same VI, the typedef is not added to the library.
Workaround: Manually add the typedef to the library.
Reported Version: 2010 32-bit Resolved Version: N/A Added: 03/05/2018
678964
Return
Nested XControls require recompile when built into Packed Project Libraries
When an XControl contains another XControl as part of its Facade.vi and is built into a Packed Project Library, it will error out and request a recompile. The recompile requires building the Packed Project Library a second time. The error will persist.
Workaround: Either avoid nesting XControls or use their source directly and do not build them into a Packed Project Library
Reported Version: 2015 SP1 Resolved Version: N/A Added: 03/05/2018
670209
Return
Changing XControl state may lock XControl permanently
When changing XControl states in ways that conflict with pre-existing properties, it is possible to lock the state typedef and all of the property VIs. Unless the workaround applies, these VIs become permanently locked and the contained typedefs will be unable to update.
Workaround: Right-click an instance of the state typedef that exists prior to the edit on non-locked VI and choose Review and Update from Typedef. This will fix all of the VIs, even locked VIs.
Reported Version: 2014 SP1 Resolved Version: N/A Added: 03/12/2018
DataSocket
624802
Return
Setting binding properties of a control within a preallocated clone subVI or XControl sets the property for all instances of the subVI or XControl
If the BindingPath property is set on a control within a preallocated clone subVI or XControl, all instances of the controls in the subVI or XControl update their BindingPath rather than the one where the property was set
Workaround: Create a unique SubVI or XControl for each instance
Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017
Example Programs
542436
Return
Block Diagram Cleanup on the Receive Message.VI in Actor Framework can cause an access violation crash within LabVIEW.
Opening
Reported Version: 2015 Resolved Version: N/A Added: 08/08/2016

External Code153731
ReturnUnhandled Exception can occur if absolute path for system DLL used in CLFN
If you use a specific path to a system DLL (C:windowssystemuser32.dll) and build your VI into an application it will create a copy of the DLL inside the application. This can cause an unhandled exception when running
Workaround: LabVIEW searches in the system directory when looking for DLLs. If you are using a system DLL simply put the name in the in DLL Path box in the CLFN properties. In the example above you would simply put 'user32.dll'

Reported Version: 8.6 Resolved Version: N/A Added: 07/23/2010

509876
ReturnBundle by Name function can send wrong pointer into subVI with Call Library Function Node
If a main VI has the output of a Bundle by Name function connected to a subVI, a Call Library Function node within the subVI can receive the wrong pointer from the wired cluster.
Workaround: Remove the Bundle by Name function or the subVI
OR
Replace the control input to the Bundle by Name function with a constant

Reported Version: 2013 SP1 Resolved Version: N/A Added: 08/08/2016

634531
ReturnTemplate methods in a C++ DLL do not appear in the Function Name drop down list of the Call Library Function Node.
Some C++ DLLs include methods which are created from a template during compilation. These template methods will not appear in the list of function names when using the Call Library Function Node.
Workaround: 1. Create wrapper functions that call the template methods, then call the wrapper functions using the Call Library Function Node.
2. Manually specify the function prototype in the function name field of the Call Library Function Node.

Reported Version: 2015 SP1 Resolved Version: N/A Added: 04/18/2017

File I/O47819
3N68LE00
Return2GB file size limit of datalog files
The maximum size of datalog files is 2 GB.
Workaround: N/A

Reported Version: 8.0 Resolved Version: N/A Added: 09/01/2007

243468
ReturnDefault Namespaces not supported in XML Parsing VIs
When trying to work with XML Parsing VIs you will get error -2768
Possible reason(s):
LabVIEW: The XPath expression does not conform to XPath syntax. Refer to the W3C
XPath Web site at http://www.w3.org/TR/xpath for more information about XPath syntax.
Workaround: Remove the default namespace (example: remove xmlns='http://www.ieee.org/ATML/2007/TestResults'),

Reported Version: 2010 32-bit Resolved Version: N/A Added: 08/17/2010

239631
ReturnMemory Growth with TDMS Write
With the standard TDMS API, when TDMS Write VIs are executed the API will build a cache in memory. This may present as a memory leak, as this memory is only cleared in specific situations.
Workaround: See Memory Growth with TDMS Write for more information.

Reported Version: 2009 Resolved Version: N/A Added: 04/27/2012

437390
ReturnFile Path control does not display 'Browse' dialog if Start Path is an invalid network path.
LabVIEW may hang while waiting for Windows to locate an invalid network directory. The control's owning VI may hang while it searches for the directory, or it may appear that the 'Browse' button does not have any affect and does not invoke a dialog. This can happen if the Start Path input in Browse Options.. is an invalid path or if the Start Path in blank and the control's value is invalid.
Workaround: Make sure the Start Path input is valid before selecting the Browse button. If the Start Path input is blank, change the File Path control's value to a known valid path before browsing.

Reported Version: 2012 Resolved Version: N/A Added: 03/24/2014

492341
ReturnLabVIEW TDMS Advanced Asynchronous Write does not return error when target disk is full.
N/A
Workaround: Use the TDMS Reserve File Size Function to allocate disk space before writing

Reported Version: 2014 Resolved Version: N/A Added: 12/01/2014

504716
ReturnAdvanced Asynchronous Write function does not return an error when target disk is full or removed
N/A
Workaround: Use the TDMS Reserve File Size Function to allocate disk space before writing

Reported Version: 2014 Resolved Version: N/A Added: 08/08/2016

528963
ReturnFile Dialog Express VI crashes when passed a null hex string as the pattern input
The File Dialog Express VI crashes LabVIEW when a null string is passed as the pattern (all files) input. The crash report states that an 'Exception: Noncontinuable exception (0xC0000025) at EIP 0x000000' occurs.
Workaround: Avoid passing the hexadecimal code for a null string to this input terminal. Programmatically detect these error situations and handle them appropriately.

Reported Version: 2013 SP1 Resolved Version: N/A Added: 08/08/2016

544623
ReturnLabVIEW 64-bit for Mac OS can improperly create special characters.
LabVIEW 64-bit for Mac OS improperly creates special characters such as the 'degree' symbol and 'micro' symbol that cannot be read correctly.
Workaround: Avoid using special characters.

Reported Version: 2015 Resolved Version: N/A Added: 08/08/2016

574329
ReturnError 4 thrown in executable but not in development environment
Sometimes after manipulating the format specifier on the Open/Create/Replace primitive and then saving and reopening the VI, the VI can throw Error 4: End of File encountered on the next run. This may also occur when the application is run as an executable.
Workaround: N/A

Reported Version: 2015 Resolved Version: N/A Added: 08/08/2016

602529
ReturnOpen/Create/Replace File does not return an error when attempting to create a file name that is restricted by the OS
When attempting to create a file with the Open/Create/Replace File primitive, the file will not be created but LabVIEW will not return an error. Examples of file names that are restricted by the OS are COM8.txt, LPT4.txt, etc.
Workaround: N/A

Reported Version: 2010 SP1 Resolved Version: N/A Added: 05/22/2017

616849
ReturnLabVIEW files are saved without an extension after attempting to save with an invalid character
If you attempt to save a LabVIEW file with an invalid character (such as ?), the file is correctly not saved. However, if you remove the invalid character and save the file, it will be saved with no extension on disk.
Workaround: After saving, add the correct extension to the file

Reported Version: 2010 SP1 Resolved Version: N/A Added: 05/22/2017

618568
ReturnReference leaks with the Audio DataPlugin
Calling the Write Data [Channel] Express VI with the Audio DataPlugin in a loop causes LabVIEW to leak references, causing memory growth over time
Workaround: N/A

Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017

629032
ReturnWiring a 2D array with an empty string to the property names input of the TDMS Set Properties function causes data for that channel to be unreadable
If a 2D array with an empty string is wired to the property names input of the TDMS Set Properties function, the TDMS Read function is unable to retrieve data from the channel with the empty name. The TDMS Read function will return error 1.
Workaround: Do not include empty strings in the 2D array of property names

Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017

640089
ReturnDETT reports a reference leak when using the Open Data Storage express VI and Close Data Storage express VI
N/A
Workaround: N/A

Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017

641269
ReturnInterleaved TDMS Write with duplicate channel names fails to write data without returning an error
If you use the interleaved data layout with a TDMS Write, passing duplicate channel names in an array can cause some data to not be written to the TDMS file.
Workaround: Use unique channel names in your array, or place the TDMS Write into a For Loop and index through each channel individually

Reported Version: 2010 SP1 Resolved Version: N/A Added: 05/22/2017

Functions, VIs, and Express VIs39161
401FEQTL
ReturnThe device ID input of the Play Sound File VI does not work on Windows
On Windows, LabVIEW ignores the device ID input of the Play Sound File VI. This VI plays sound only on the default sound card.
Workaround: Use the Sound Output Configure VI and the Sound Output Write VI with the Sound File Open VI and the Sound File Read VI or the Sound File Simple Read VI. Refer to the Sound File to Sound Output example VI for an example of this workaround.

Reported Version: 8.0.1 Resolved Version: N/A Added: 09/01/2007

48016
3P7CBB4Q
ReturnUnsigned int32 loses value in formula node when you write to the most significant bit
If you wire a hex value greater than x7FFFFFFF as an unsigned, 32-bit integer to a Formula Node, LabVIEW coerces the value to 0. If you use a negative number for U32 input/output variable, LabVIEW will coerce the value to 0.
Workaround: 1. Use the Mathscript node or LabVIEW code for the operation that involves an unsigned, 32-bit integer.
2. Use signed 32-bit integers instead of unsigned 32-bit integers in the formula node.

Reported Version: 8.0 Resolved Version: N/A Added: 09/01/2007

50420
44CG88SN
ReturnUpdate the Pulse Transition Measurement Express VI
The terminology and measurement definitions for the Transition Measurements VI comply with IEEE Standard 181-2003, IEEE Standard on Transitions, Pulses, and Related Waveforms. However, the Timing and Transition Measurements Express VI does not comply with this IEEE Standard.
Workaround: The Slew rate refers to the transition slope. The Preshoot refers to the pre-transition undershoot (rising pulse) or the pre-transition overshoot (falling pulse). The Overshoot refers to the post-transition undershoot (rising pulse) or the post-transition overshoot (falling pulse).

Reported Version: 8.5 Resolved Version: N/A Added: 09/01/2007

120686
ReturnWrite to LabVIEW Measurement Files (LVM) using Express VIs takes up a lot of memory
The 'Write to Measurement File' Express VI consumes a large amount of memory when writing to a Text File (LVM). However, the memory usage is smaller when the same Express VI is used to write a TDM/TDMS File
Workaround: Use general LabVIEW VIs (and not Express VIs) to perform an LVM write for large amounts of data. The other option would be to write in smaller chunks.

Reported Version: 7.1 Resolved Version: N/A Added: 08/11/2008

213279
ReturnSome nodes may crash or yield incorrect/inconsistent results when Inlined
An Inline public methodVI calling a private-scope method VI, inlined into a non-class caller may give a runtime error when trying to call the private method from the inlined code in the non-class caller.
Workaround: Do not try to Inline VIs with these nodes.

Reported Version: 2010 32-bit Resolved Version: N/A Added: 02/19/2010

227030
ReturnWait on Notification from Multiple function has unexpected behavior when ignoring previous input.
Workaround: See KB

Reported Version: 8.0 Resolved Version: N/A Added: 07/23/2010

235019
ReturnOpenSSL fatal error when LabVIEW exits
The OpenSSL fatal error possibly occurs when using Search features in LabVIEW for the first time after installation.
Workaround: Launch LabVIEW and exit when Getting Started Window opens. The error now goes away in future launchings.

Reported Version: 2010 32-bit Resolved Version: Unknown Added: 08/03/2010

196607
ReturnDTbl Replace Subset VI behavior change between LabVIEW 8.6.1 and 2009
The start input indexes from the replacement data instead of the existing data
Workaround: Set the index of data to replace from 0

Reported Version: 2009 32-bit Resolved Version: N/A Added: 10/01/2010

322914
ReturnFormula VI does not execute pow(x,y) function
Workaround: Use the formula node to use the pow(x,y) function. If you need to change this programmatically, use the Power of X function in G code.

Reported Version: 2009 32-bit Resolved Version: N/A Added: 10/01/2010

289842
ReturnGet Variant Attribute VI returns wrong value if attribute not found
The default value that's returned by the Get Variant Attribute VI is not blank when nothing is wired to the default value terminal. The Get Variant Attribute instead seems to return the last/previous value it returned as the default value.
Workaround: Use the Found? output and logic to return a blank variant if necessary

Reported Version: 8.6.1 Resolved Version: N/A Added: 03/21/2011

279373
ReturnSMTP has been updated to use port 587; LabVIEW makes use of legacy port 25
The SMTP has been updated to use port 587 instead of port 25. LabVIEW still makes use of port 25 with its SMTP VIs.
Workaround: Open any SMTP VI, and find the SMTP_CreateSession.vi. Open that VI, you will find a numeric constant on the block diagram that is set to 25.

Reported Version: 2010 32-bit Resolved Version: N/A Added: 08/02/2011

359662
ReturnSome dotted scripting property calls can crash LabVIEW if earlier properties error
If you access the property LinkedControl.ClassName on an object that does not have a linked control error 1308 will be thrown. If you access the property 3 times, LabVIEW will crash.
Workaround: Separate into two calls; e.g. change a property of LinkedControl.ClassName into a call to LinkedControl, which emits a reference and, if successful, wire that to a second property node to get ClassName.

Reported Version: 2010 SP1 32-bit Resolved Version: N/A Added: 07/11/2012

202192
ReturnLabVIEW UDP broadcast is inconsistent across different OS's.
If the UDP Open VI has 0.0.0.0 wired to the Net Address terminal, the behavior varies with OS. Windows XP and NI ETS will send on all interfaces, while Windows Vista, Windows 7, VxWorks, and Linux will send on the default interface.
Workaround: N/a

Reported Version: 8.6.1 Resolved Version: N/A Added: 07/24/2012

335576
ReturnPlay Waveform Express VI gives error 4803 with Sample Rate 3125, 6250, 12.5K, 25K, 50K, 100K, 200K Hz
n/a
Workaround: Instead of using the 'Play Waveform' Express VI, use the code from the example Generate Sound.vi.

Reported Version: 2010 SP1 32-bit Resolved Version: N/A Added: 08/03/2012

353261
ReturnConditional Indexing Terminal on Parallel For Loop with Shift Registers Runs with 'Memory is Full Error'
Workaround: Use the Build Array in a Case structure

Reported Version: 2012 32-bit Resolved Version: N/A Added: 08/03/2012

381656
ReturnAdding or subtracting timestamps causes a conversion to double and precision loss
N/A
Workaround: Cast the timestamps to clusters of U64 'seconds since epoch' and I64 'fractions of a second' before the operation and then cast back to timestamp after the operation

Reported Version: 2011 Resolved Version: N/A Added: 01/29/2013

391784
ReturnMemory Lead when Sound VIs are Called Dynamically
Sound Input Configure.vi and Sound Input Clear.vi leak memory when called dynamically
Workaround: Use a static call to these VIs.

Reported Version: 2012 Resolved Version: N/A Added: 08/02/2013

392545
ReturnTimed Loop crashes LabVIEW after exiting
A timed loop that meets these criteria can crash LabVIEW after finishing execution.
1) The Timed Loop must write to the 'Offset' input node inside the loop
2) The Timed Loop must have set the 'Mode' input node to anything else other than 'No Change' or 'Discard missed periods, ignore original phase' before the loop begins
Workaround: Configure the Timed Loop once at the beginning of execution instead of each iteration.

Reported Version: 2012 Resolved Version: N/A Added: 08/02/2013

406311
ReturnVI.Control Value.Set will Crash LabVIEW When Value Non-Variant Data is Used for Value Parameter
The crash will happen when VI.Control Value.Set is invoked upon a VI reference that has been opened by Open VI Reference.
Workaround: Cast data to variant before wiring to Value parameter.

Reported Version: 2012 Resolved Version: N/A Added: 08/02/2013

407633
ReturnSet Cell Value Method Returns Error 1604
Set Cell Value method for tables returns error 1604 if method executes at the same time that a user changes the value of a Picture Ring Control.
Workaround: Architect code so table is not updating continuously to reduce risk that user changes Picture Ring value at the same time that Set Cell Value is executing.

Reported Version: 2012 SP1 Resolved Version: N/A Added: 08/02/2013

410904
ReturnPrint.VI to Printer Method Always Prints Header in LabVIEW Built Applications
The Page Headers? parameter for Print.VI to Printer is always true when running as a LabVIEW Built Application. The parameter is used properly when the method is ran in the LabVIEW development environment.
Workaround: 1. Select Operate»Print at Completion to print the front panel of a VI when it finishes running.
2. Select File»VI Properties.
3. Select Print Options from the Category pull-down menu.
4. Place a checkmark in the Automatically Print Panel Every Time VI Completes Execution checkbox.
5. Uncheck Print header (name,date,page number) box
6. Click the OK button.

Reported Version: 2012 SP1 Resolved Version: N/A Added: 08/02/2013

412979
ReturnFlatten to XML String does not properly escape single and double apostrophes in a string input (' and ')
These should be escaped to 'apos' and 'quot' but are not. Other special characters including &,<, and > are correctly escaped.
Workaround: Parse the string manually for apostrophes to escape them

Reported Version: 2012 SP1 Resolved Version: N/A Added: 10/17/2013

390021
ReturnAn inlined VI can not be placed on the block diagram of a VI with subroutine priority unless it also has subroutine priority
Inlined VIs should ignore the Priority setting in VI properties, however an inlined VI dropped in a subroutine priority VI will break the run arrow unless the inlined VI is also set to subroutine priority.
Workaround: Set the inlined subVI to subroutine priority

Reported Version: 2012 Resolved Version: N/A Added: 03/11/2014

384591
ReturnA password protected VI accessing a password protected community scoped VI is broken if the VIs are set to separate compiled code from source code
This only happens if the VI source-only option set to true: Tools -> Options -> Environment Settings -> Separate Compiled Code from New Files set to true, or via the VI Properties window
Workaround: Do not separate the compiled code from the source code or remove the password

Reported Version: 2011 SP1 Resolved Version: N/A Added: 05/09/2014

442745
ReturnRF-RIO Instr Default Personality 5646R.lvproj's FPGA VI will hang on save.
Instrument driverRFSA5645RPublicApply Digital Correction.vi located in RF-RIO Instr Default Personality 5646R.lvproj will hang on save. This happens when removing the diagram disable structure. In addition, the VI cannot compile.
Workaround: Currently, using the structure wrap included in the example code is recommended. If you only use one instance of the polymorphic VI, re-arrange the instances such that the instance you wish to use appears first in the list.

Reported Version: 2013 Resolved Version: N/A Added: 07/31/2014

467735
Return'Format into File' produces Error 1 when appending to a file that has a size of 4 GB
See this NI Community page for more information.
Workaround: Use 'Format Into String' and 'Write to Binary File'.

Reported Version: 2013 Resolved Version: N/A Added: 12/01/2014

510218
ReturnCreate Mask.vi does not work in conjunction with the Get Image Subset.vi in LabVIEW
N/A
Workaround: Swap the Dimension Size inputs of the Reshape Array in the Case Structure at the bottom of Get Image Subset.vi.

Reported Version: 2012 SP1 Resolved Version: N/A Added: 06/17/2015

515300
ReturnNamedBundler function in LV Scripting does not work properly when the reference is opened from a New VI function
N/A
Workaround: Use the Open VI Reference and Save A Copy functions, rather than New VI function, to create a new instance of a vi from a template.

Reported Version: 2014 Resolved Version: N/A Added: 06/17/2015

525685
ReturnError -2628 is returned when parsing an XML file with a Document Type Definition file
N/A
Workaround: N/A

Reported Version: 2014 Resolved Version: N/A Added: 06/17/2015

570754
ReturnLinear Fit produces NaN result if X input value is too large
Linear Fit produces NaN result if X input value is too large. Values above around 2.2x10^9 in LabVIEW 32 bit or 4.9x10^7 in LabVIEW 64 bit may exhibit this behavior.
Workaround: Modify your data to smaller absolute values before using this function.

Reported Version: 2015 Resolved Version: N/A Added: 06/10/2016

521856
ReturnRare LabVIEW crash when using 'Panel Close?' filtering event and 'Quit LabVIEW' function
N/A
Workaround: Either do not use the 'Panel Close?' event, do not open the front panel of the VI being closed, or turn off scrollbar visibility using a property node.

Reported Version: 2014 SP1 Resolved Version: N/A Added: 08/08/2016

552304
ReturnSMTP Client VI Example incorrectly converts some characters when placed in subject line
Email sent using the SMTP Client VI shipping example converts '!', ':', and '~' to '?' in the subject line of emails.
Workaround: N/A

Reported Version: 2013 SP1 Resolved Version: N/A Added: 08/08/2016

571353
ReturnXNode can cause Dirty Dot when no parameters are modified
When abilities of XNodes are called, LabVIEW can erroneously report that changes have been made to the VI and prompt the user to save.
Workaround: N/A

Reported Version: 2015 Resolved Version: N/A Added: 08/08/2016

603204
ReturnWhen using a cylindrical coordinate system on a 3D scatter plot, the color ramp legend does not reflect the displayed color gradient
After changing the coordinate system to cylindrical, the graph will correctly display the color gradient according to distance from the origin. However, the legend will display the color ramp based on the minimum and maximum values of the z axis.
Workaround: N/A

Reported Version: 2015 SP1 Resolved Version: N/A Added: 05/22/2017

607058
ReturnFlattening an EXT representation numeric to JSON causes loss of precision
N/A
Workaround: Use Format Into String followed by Flatten to JSON

Reported Version: 2013 SP1 Resolved Version: N/A Added: 05/22/2017

613423
ReturnRegistering for an event for multiple boolean controls can fail in specific configurations
When passing a mixture of strict and non-strict boolean references in a cluster to the event source terminal of the Register For Events node, the input wire will break if any strict references are not the first elements of the cluster.
Workaround: Use a Switch mechanical action, group the references with Build Array, or place any strict references at the beginning of the cluster.

Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017

617826
ReturnLabVIEW will not generate a Key Down event if the mouse is held down on a cell inside a table control
If you hold the left mouse button down on a cell inside of a table control, LabVIEW will not generate a Key Down event on the first key press. Subsequent key presses will generate the event as normal
Workaround: N/A

Reported Version: 2015 SP1 Resolved Version: N/A Added: 05/22/2017

627783
ReturnUsing TCP Open Connection with a Timeout of 0 can cause connection failures
When you specify a Timeout of 0 for TCP Open Connection, it will return error 56. However, in some cases, a connection can still be established. This will cause subsequent connection attempts to fail, even when they have a nonzero timeout.
Workaround: Always use nonzero timeouts

Reported Version: 2010 SP1 Resolved Version: N/A Added: 05/22/2017

640089
ReturnDETT reports a reference leak when using the Open Data Storage express VI and Close Data Storage express VI
N/A
Workaround: N/A

Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017

634261
ReturnThe Block Diagram.Get Image Scaled method displays subVIs as black rectangles if the image depth is less than 8.
Workaround: Use a depth greater than 8

Reported Version: 2017 Resolved Version: N/A Added: 01/23/2018

654057
ReturnWhen using clusters with a reference to the same control to register for multiple events, LabVIEW does not properly handle all events.
After bundling a control reference into a cluster and registering for different events using the same cluster, only the first event registered will be handled by the event structure.
Workaround: Use separate Register for Events nodes for each event you want to register for, then bundle the event registration refnums into a cluster

Reported Version: 2017 Resolved Version: N/A Added: 01/23/2018

655865
ReturnThe VI Method Save.For Previous fails to maintain the status of the 'Separate compiled code from source file' attribute
When you use the Save.For Previous method on a VI with the 'Separate compiled code from source file' attribute set to true, the saved VI will have this attribute set to false.
Workaround: Saving for previous through the File menu works as expected

Reported Version: 2016 Resolved Version: N/A Added: 01/23/2018

656572
ReturnIn some cases, some primitives may not properly display coercion dots when converting between integer representations
Workaround: N/A

Reported Version: 2012 SP1 Resolved Version: N/A Added: 01/23/2018

631422
ReturnRegenerate Channel Instances stop responding
In some situations, channel wires can hang LabVIEW when trying to regenerate channel instances. The hang will not end until LabVIEW is forced to close.
Workaround: Open smaller subVIs containing channel wires first allowing the channels to regenerate. Once all of these are complete, open the calling VI. The smaller instances already regenerated their channel instances.

Reported Version: 2017 Resolved Version: N/A Added: 03/12/2018

677020
ReturnChannel wires do not update minor changes in data type
Minor changes in elements passed to a channel wire do not automatically update the data type on the wire. As an example, changing the name of a string contained in a cluster will not update the type. Creating an indicator from the channel wire will still show the original names of the cluster.
Workaround: Changing the input data type to a Strict Type Definition will ensure the names always match. If this isn't possible, using queues instead of channel wires will update as expected.

Reported Version: 2017 Resolved Version: N/A Added: 03/12/2018

686273
ReturnSound Output VIs can cause LabVIEW to freeze on Mac OS
Using Sound Output Stop followed by Sound Output Write can cause LabVIEW to freeze when developing for Mac OS.
Workaround: Use the Clear Buffer VI and then re-initialize task to restart the sound rather than pause playback.

Reported Version: 2016 Resolved Version: N/A Added: 03/12/2018

I/O Servers638070
ReturnLabVIEW crashes when calling the Children[] Property Node in a VI with reentrancy set to 'Shared clone reentrant execution.'
N/A
Workaround: Use the Search Variable Container VI instead of the Children[] Property Node. The regular expression and class inputs can help filter the results.

Reported Version: 2015 SP1 Resolved Version: N/A Added: 05/22/2017

Installation and Activation583670
ReturnIf LabVIEW 2016 is installed, installers built in any version of LabVIEW will not work on Windows 7 RTM and older
See the following KB for details: http://knowledge.ni.com/KnowledgeArticleDetails?id=kA00Z0000019LkCSAU
Workaround: Do not install LabVIEW 2016 on a computer which builds installers for Windows 7 RTM, Windows Vista, Windows XP SP3, and older.

Reported Version: 2015 SP1 Resolved Version: N/A Added: 08/08/2016

LabVIEW Environment105509
ReturnThe 'do not save automatic changes' setting does not affect libraries
The 'do not save automatic changes' options setting does not affect any type of library, including classes.
Workaround: N/A

Reported Version: 8.0 Resolved Version: N/A Added: 06/20/2008

95055
ReturnSave for previous fails if file path is too long
Save for previous copies the folder being saved to a temp location; if the resulting file paths exceed the limit defined by the OS, the function fails.
Workaround: Copy the folder being saved to the root directory to reduce the file path length and Save for Previous from that location.

Reported Version: 8.5 Resolved Version: N/A Added: 11/17/2009

256141
ReturnWindows 7 often shows '(Not Responding)' and will bring other windows to the front during expensive operations
If Windows 7 if a window is unresponsive to user input (e.g. mouse clicks) for five seconds it will ghost the window and display '(Not Responding)'.
Some operations in LabVIEW run in the UI thread. This is to prevent different operations from happening in parallel (e.g. compiling, edit operations, saving, drawing, etc.). Because large block diagrams can take longer than five seconds to compile or run clean up on Windows can tag LabVIEW as Not Responding.
In some cases the ghosted window can move behind the other open windows when it finishes it task.
Workaround: Wait until the expensive task as finished before trying to interact with the window.

Reported Version: 2009 32-bit Resolved Version: N/A Added: 10/28/2010

238713
Return3D Picture Controls can display transparently or crash LabVIEW on certain graphics cards
The 3D Picture Control is built on a OpenSceneGraph which uses OpenGL. Several reports of the 3D picture control crashing LabVIEW have been reported. In almost all cases it was an Intel integrated graphics card involved. This crash is caused by an incompatibility of the graphics hardware.
Note: Many of the 3D Graphs use the 3D Picture Control
Workaround: There have been several things that have worked for users:

  •  
  • Update the video driver
  •  
  • Turn on/off hardware acceleration
  •  
  • Turn on Aero in Windows 7
  •  
  • Turn off Aero in Windows 7
  •  

 

Reported Version: 2009 32-bit Resolved Version: N/A Added: 04/20/2011

257194
ReturnConnector pane of a VI can change from LabVIEW 2009 to LabVIEW 2011
If you have a VI with no items in the connector pane and upgrade it straight form LabVIEW 2009 to LabVIEW 2011 then the connector pane may change
Workaround: Open in LabVIEW 2010 first

Reported Version: 2011 32-bit Resolved Version: N/A Added: 08/02/2011

244551
ReturnEditing large strict type definitions can take a long time to update
When large type definitions are updated, all instances in memory require an update. This update can take many minutes for very large type definitions.
Workaround: Use smaller type definitions, or consider using LabVIEW classes to contain your type data.

Reported Version: 7.1.1 Resolved Version: N/A Added: 07/23/2012

369142
ReturnFront Panels may stop updating with 3+ monitors with Windows Aero enabled
With Windows Aero enabled on a machine with 3 or more monitors the front panel may stop drawing. This issue has been seen in limited cases and is usually after hours of operation. The application itself continues to run. Moving or minimizing the window causes it to start updating again.
Workaround: Disable Windows Aero by selecting a non-Aero theme.

Reported Version: 2010 SP1 Resolved Version: N/A Added: 09/01/2012

305978
ReturnSave As Duplicate with Include All Dependencies makes a Copy of the instr.lib Folder.
Include All Dependencies option in Save As does not ignore files from laviewinstr.lib folder.
Workaround: Choose 'Select contents to copy' and uncheck instr.lib

Reported Version: 2010 32-bit Resolved Version: N/A Added: 08/02/2013

408790
ReturnPalette Editor Cannot Add LabVIEW Classes
LabVIEW Classes are an available option to be added to palettes, but adding them will not take effect.
Workaround: If your goal is to allow dropping of the class control or constant, you can create a custom control (not a typedef) that has the class on it's panel and add the custom control to the palettes. If your goal is to add the LabVIEW Class as a linked library, you can do so programmatically with Write Palette.vi.

Reported Version: 2009 Resolved Version: N/A Added: 08/02/2013

430758
ReturnIt is not possible to save a VI with the name of another VI in memory, even if they are in different libraries
LabVIEW does not check the library namespace when determining if a VI is being saved with a name that is already in use. If a VI is in memory, it is not possible to save another VI with the same name in the same project even if they are in different libraries.
Workaround: Close the other VIs with the same name so they are not in memory.

Reported Version: 2013 Resolved Version: N/A Added: 03/14/2014

478232
ReturnIn certain cases, LabVIEW may incorrectly crisscross wires during loop creation
When adding a loop around existing code, LabVIEW may reconnect wires to the incorrect tunnels on the border of the loop
Workaround: Manually reconnect the appropriate wires and tunnels

Reported Version: 2014 Resolved Version: N/A Added: 06/19/2014

470218
ReturnLabVIEW (64-bit) for Mac, does not show the login prompt for Revision History when starting LabVIEW
In Tools>>Options, you can set the 'User Name to Record in VI Revision History' to 'LabVIEW registration name' which adds the token 'history.whereToGetName=LabVIEW' to the LabVIEW.ini or LabVIEW.app file, for Windows and Mac OS X respectively. Changing the token to 'history.whereToGetName=prompt' should invoke a login dialog each time LabVIEW starts, but the dialog does not appear in LabVIEW (64-bit) for Mac.
Workaround: After LabVIEW finishes launching, select Tools>>User Name to view the login dialog.

Reported Version: 2014 Resolved Version: N/A Added: 07/28/2014

420582
ReturnTyping Obtain in Quick Drop populates with an unexpected selection
N/A
Workaround: Disable 'relevancy-based search' in the Quick Drop configuration options

Reported Version: 2013 Resolved Version: N/A Added: 07/31/2014

584837
ReturnMass compiling a project from project explorer in certain cases can cause LabVIEW to hang.
Mass compiling a project from project explorer with an unsaved VI can cause LabVIEW to hang.
Workaround: N/A

Reported Version: 2012 SP1 Resolved Version: N/A Added: 04/29/2016

457854
ReturnAborting a VI can leave VIs targeted by a Call By Reference node reserved permanently
N/A
Workaround: Close the project to unreserve the VI

Reported Version: 2013 Resolved Version: N/A Added: 08/08/2016

542436
ReturnBlock Diagram Cleanup on the Receive Message.VI in Actor Framework can cause an access violation crash within LabVIEW.
Opening Reported Version: 2015Resolved Version: N/AAdded: 08/08/2016544257
ReturnInplace issue can occur when using LabVIEW 32-bit on a 64-bit operating system.
Running a VI that calls a subVI containing a Call Library Function Node to the kernel32.dll IsWow64Process can cause the returned value of the dll to be incorrect.
Workaround: Adding an 'Always Copy' dot before the control that is wired to the Front Panel Terminal within the subVI fixes the issue.

Reported Version: 2014 Resolved Version: N/A Added: 08/08/2016

558891
ReturnIn some scenarios, LabVIEW Menu positions within a VI or project are offset in Windows 10
For multiple displays, Windows 10 allows you to set different 'size for text and other items' (magnification) for each display. In the case you have different magnifications between displays, the drop down menus of a VI or project are offset to the right and down. This can be dramatic (even off the screen) when the two magnifications are very different.
Workaround: Use a consistent magnification level for all displays.

Reported Version: 2014 SP1 Resolved Version: N/A Added: 08/08/2016

578085
ReturnSaving a very large VI in LabVIEW 2015 and later can take longer than in previous versions
When compared to save times in earlier versions of LabVIEW, saving a large VI in LabVIEW 2015 and later takes a longer amount of time to complete.
Workaround: Try the steps listed in this KB to minimize save time: http://ae.natinst.com/public.nsf/web/searchinternal/e43b32c14030c3b686256c1e0044d9b6?OpenDocument

Reported Version: 2015 Resolved Version: N/A Added: 08/08/2016

639524
ReturnChanging font to Application font can shrink constants inside of structures
In Japanese LabVIEW, changing the font of items on the block diagram from a non-default font to Application Font can cause constants within a structure to shrink
Workaround: Select all items on the block diagram and press Ctrl+1 to set them to Application Font again

Reported Version: 2014 SP1 Resolved Version: N/A Added: 05/22/2017

678334
ReturnChanging the keyboard shortcut of the Bookmark Manager to Ctrl+Shift+3 does not launch the Bookmark Manager when the shortcut is pressed.
Workaround: N/A

Reported Version: 2013 SP1 Resolved Version: N/A Added: 01/23/2018

LabVIEW Object Oriented Programming52027
4A4GRP00
ReturnCannot use the 'New>>VI for Override..' dialog to create override of password-protected VI unless you have the password
You use the 'New>>VI for Override..' dialog to override an ancestor VI in a LabVIEW class if the VI you want to override is password-protected.
Workaround: Make a public VI which wraps the functionality of the private VI, and instruct others to override the public VI.

Reported Version: 8.5 Resolved Version: N/A Added: 09/01/2007

103315
ReturnCreating a circular link between an Xcontrol and a LVClass can crash LabVIEW.
The circular load leads to VIs that are permanently broken and no matter what you do the run arrow will not become fixed.
Workaround: Do not create a circular link from your XControl to your class. In other words, write your class completely and then write your XControl using the class. Do not put the XControl or any property/invoke node for the XControl into member VIs of the class.

Reported Version: 8.5.1 Resolved Version: N/A Added: 11/17/2009

245148
ReturnClass Properties dialog sometimes throws timeout error 123 when opening and must be restarted
In LV 2010, there appears to be a timing race condition in the Class Properties dialog for LabVIEW classes. Every once in a while if you try to launch the dialog, the dialog will throw an error dialog reporting error 123 that the dialog has timed out while trying to launch. After you dismiss the dialog, you may see a secondary error dialog. Once you dismiss that, you can relaunch the Class Properties dialog and will generally succeed. There is no danger to your class and no corruption to you class file has occurred. It is solely a bug in trying to launch the dialog.
Workaround: Hit Continue or OK button to dismiss all error dialogs that come up then retry opening the Class Properties dialog.

Reported Version: 2010 32-bit Resolved Version: N/A Added: 02/18/2011

284936
ReturnBreaking one Override VI in LVOOP shows all siblings as broken but does not explain why
When using OOP in LabVIEW, breaking the connector pane of a child class Override VI will make all of its sibling override VI's appear broken even though they are not broken. Hitting run on the broken Run Arrow of any child class Override VI will list all of the child class VIs in the list of 'Items with Errors', but none of them will have an error associated with it except for the broken ones.
Workaround: Use the red X in the errors window to find the actual broken VI

Reported Version: 8.6.1 Resolved Version: N/A Added: 04/20/2011

233061
4AQA5L00
ReturnLabVIEW crashes after working with Simulation Subsystem using a LabVIEW Class
Sometimes LabVIEW will crash after working with a Simulation Subsystems that has a LabVIEW Class as one of its controls or indicators on its connector pane. Usually it is only a problem when working with the Subsystem's caller within a LabVIEW Project. The crash will occur after closing the project, while returning to the initial LabVIEW window.
Workaround: Save all work before closing the LabVIEW Project when using LabVIEW Simulation and Classes together.

Reported Version: 2010 32-bit Resolved Version: N/A Added: 11/10/2011

356656
ReturnCrash when compiling VIs that call into a certain class based VI hierarchies
Some VIs that call into a formerly non-dynamic dispatch member of a class whose parent is missing may crash when saved or mass compiled.
Workaround: Open the class first, then open the VI and save it.

Reported Version: 2011 32-bit Resolved Version: N/A Added: 08/03/2012

391455
ReturnApplying an icon to LabVIEW class overwrites the icons of its methods
The icon for a LabVIEW class appears to be only the banner, but when it is applied it overwrites the entire icon of the method VIs
Workaround: N/A

Reported Version: 2012 Resolved Version: N/A Added: 08/02/2013

410360
ReturnLabVIEW Classes Become Corrupt When Multiple Files With Same File Name are Added to the Class
When a LabVIEW Class is saved with multiple files sub-files that have the same file name, the .lvclass file will become corrupt.
Workaround: N/A

Reported Version: 2012 SP1 Resolved Version: N/A Added: 08/02/2013

461969
ReturnWhen using a class containing a DAQmx Physical Channel control, it will not properly load that information from an XML file.
The control can be changed and saved to the XML as expected and seen when opening the XML. However, when you try to load the channel from the XML it appears blank.
Workaround: If you place the class cluster in an additional cluster the DAQmx Physical Channel control saves and loads as expected.

Reported Version: 2013 Resolved Version: N/A Added: 05/07/2014

432523
ReturnReordering elements of a cluster within the private data of a class can break VIs that reference the class
If you have a cluster within the private data of a class and you reorder the elements of the cluster, VIs that reference the class can become broken.
Workaround: Close and reopen the LabVIEW project after reordering the cluster

Reported Version: 2013 Resolved Version: N/A Added: 05/22/2017

633648
ReturnLabVIEW crashes when replacing the Actor Framework library with a packed library
Building a packed library from the Actor Framework libraries and selecting 'Replace with packed library..' in a project crashes LabVIEW.
Workaround: N/A

Reported Version: 2016 Resolved Version: N/A Added: 01/23/2018

686080
ReturnReplacing ActorFramework.lvlib with a packed project library causes LabVIEW crash
Replacing the ActorFramework.lvlib with a built version of ActorFramework.lvlibp in any project puts LabVIEW into an unstable state and leads to a crash breaking Actor Framework.
Workaround: Delete the AFDebug folder from resource. Delete the ActorFramework folder from vi.lib. Repair the LabVIEW installation.

Reported Version: 2017 SP1 Resolved Version: N/A Added: 03/12/2018

686379
ReturnObjects flattened to XML may revert data to default value
When passing a class to the Flatten to XML VIs, data may be reverted to the default value rather than the value passed on when calling Unflatten from XML later.
Workaround: Wire the output from a setter VI to the Unflatten to XML instead of a constant. Use other means to flatten the VI to a generic data type.

Reported Version: 2015 SP1 Resolved Version: N/A Added: 03/12/2018

LabVIEW Project163371
Return'Save As:Copy' on a nested library breaks member VIs if use option to add copied library to owner library
Old Description :
'Save As:Copy' on a nested library breaks member VIs if use option to add copied library to owner library
If you have a nested library, a library that is owned by another library, and you use Save As:Copy, there is an option to add the duplicate library to the original owner library. If you use this option, the member VIs of the duplicate library are all broken because they are not correctly named as members of the owning library.
This bug affects all types of libraries, .lvlib, .lvclass, .xctl and .lvsc.
Workaround: Option 1: Do not use the 'add to owning library' option and instead add the duplicate library to the owner manually after the copy.
Option 2: After the copy operation, open and close one of the new VIs and then move the duplicate library out of the owner library. Browse to any missing VIs that pop up a browse dialog. Move the duplicate library back into the owner library.

Reported Version: 8.5 Resolved Version: N/A Added: 09/30/2009

232348
ReturnChanges to a library item's access scope sometimes do not update broken callers.
Changing a library item's access scope sometimes does not update callers which are broken only because they were attempting to access an item which was out of scope to them.
Workaround: Force recompile (ctrl+click on the run arrow) any VI which incorrectly believes that access scope forbids access to it's dependency. Changing the access scope to another value, then back to the desired value while the VI is open will also fix the issue.

Reported Version: 2010 32-bit Resolved Version: N/A Added: 07/23/2010

377385
ReturnError 1390 on Dynamic VI Call to Friend Library
The error is returned when two Community scoped LabVIEW Libraries are Friends to each other, and one Library performs a dynamic call to a VI in the other Library.
Workaround: Change the dynamic call to a static call, or change the scope to Public on the Library containing the callee VI.

Reported Version: 2012 Resolved Version: N/A Added: 01/28/2013

257735
ReturnClass VIs that call shared variables in a library in an auto-populating folder will not be loaded
If a VI in a class calls a shared variable that is in a library in an auto-populating folder, it will not find the shared variable when the project is loaded
Workaround: Make the folder a snapshot instead of auto-populating and reopen the project

Reported Version: 8.6.1 Resolved Version: N/A Added: 02/01/2013

408391
ReturnNon-printable Characters in the Description of Will Corrupt LabVIEW Classes and Libraries
Non-printable characters can be inserted into the description of LabVIEW Classes and Libraries with the Description Property Node. This will corrupt the .lvclass or .lvlib file.
Workaround: The .lvclass or .lvlib file can be opened in a text editor, and the description can be manually deleted to recover the files.

Reported Version: 2012 Resolved Version: N/A Added: 08/02/2013

430758
ReturnIt is not possible to save a VI with the name of another VI in memory, even if they are in different libraries
LabVIEW does not check the library namespace when determining if a VI is being saved with a name that is already in use. If a VI is in memory, it is not possible to save another VI with the same name in the same project even if they are in different libraries.
Workaround: Close the other VIs with the same name so they are not in memory.

Reported Version: 2013 Resolved Version: N/A Added: 03/14/2014

339230
ReturnNewly created typedefs are not automatically added to library
When creating a subVI from a VI contained within a library, the subVI is added to the caller VI's library. When creating a typedef from a control in the same VI, the typedef is not added to the library.
Workaround: Manually add the typedef to the library.

Reported Version: 2010 32-bit Resolved Version: N/A Added: 03/05/2018

MathScript469268
ReturnFormula Node and MathScript Node variable labels can shift to become misalligned
After opening and closing its VI, the label will no longer look centered inside its owning box
Workaround: This should not affect functionality. Recreate the variable on the node's border to recenter the label

Reported Version: 2013 SP1 Resolved Version: N/A Added: 05/02/2014

Miscellaneous389041
ReturnError -314250 from Create Network Stream Writer Endpoint
Error is returned when data type is set with a SGL value that has a unit label defined.
Workaround: Change representation or DBL, or remove the unit label.

Reported Version: 2013 Resolved Version: N/A Added: 08/02/2013

403727
ReturnRepeated Dynamic Calls to VI in Packed Project Library Can Cause Error in VI Call
After over a million Dynamic Calls to a VI contained in a Packed Project Library, a error can be thrown that LabVIEW attempted a recursive call.
Workaround: The error does not occur on regular project libraries.

Reported Version: 2011 SP1 Resolved Version: N/A Added: 08/02/2013

415924
ReturnDouble precision numeric constants set to 'bar' units sometimes use Pa units
Double precision numeric controls and indicators using 'bar' units work correctly, but block diagram constants use Pa instead of bar.
Workaround: Create the constant from a control with 'bar' units and then change the unit label from Pa to bar to get a constant that uses bar.

Reported Version: 2012 SP1 Resolved Version: N/A Added: 10/14/2013

NI Services364338
Return'Error while retrieving database: Forbidden' connecting to a RT target via the web configuration.
If you change the admin password for an RT target and reboot the target before saving, you may receive the error 'Error while retrieving database: Forbidden.'
Workaround: Refresh the web page hosting the web configuration.

Reported Version: 2012 Resolved Version: N/A Added: 08/03/2012

Operating System Specific351506
Return[Mac] Test Device option on Play Waveform Express VI Configuration page doesn't output test tone
N/A
Workaround: N/A

Reported Version: 2011 32-bit Resolved Version: N/A Added: 05/07/2012

403182
ReturnSound Output.vi Does Not Support more than 2 Audio Channels on Windows 7
Error 4811: 'can not support sound format' will be returned from the VI when executed on Windows 7.
Workaround: More than 2 Channels are supported on Windows XP.

Reported Version: 2012 SP1 Resolved Version: N/A Added: 08/02/2013

405271
ReturnBoolean Mechanical Actions Don't Work as Expected on Windows 8 Touch Screen
Switch Until Released and Latch Until Released don't behave as expected for touch and hold gesture. Boolean controls will not toggle on touch and hold gesture, until finger is dragged outside the bounds of the control. Other Boolean mechanical actions behave as expected.
Workaround: N/A

Reported Version: 2012 Resolved Version: N/A Added: 08/02/2013

462021
ReturnIn LabVIEW for Mac, filtered menu tracking is not cancelled until the event's case finishes executing
If you are the filter event 'Menu Activation?' and you discard the event, the menu activation will not be cancelled until that case in the event structure finishes executing. This may cause the menu to appear momentarily before it disappears.
Workaround: Programmatically hide or disable the menu instead of filtering an event for it.

Reported Version: 2014 Resolved Version: N/A Added: 07/31/2014

634015
ReturnCertain operations will not let the System Exec VI return on Windows 10
Certain commands, such as renaming a file, will cause the System Exec VI to indefinitely wait for a response on Windows 10. The IDE will continue to be responsive and the VI may be aborted. This will only occur with 'Wait Until Completion' is set to True.
Workaround: Set 'Wait Until Completion' parameter to False

Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017

686923
ReturnBring to Front Invoke Node may not bring window to front
Some operating systems will bring the window in front of all LabVIEW windows but not any other windows. If LabVIEW is not the active window at the time of this call, the window may not come on top of other running windows.
Workaround: Use operating specific calls to find the window and bring it in front of all other windows.

Reported Version: 2017 Resolved Version: N/A Added: 03/05/2018

Performance390021
ReturnAn inlined VI can not be placed on the block diagram of a VI with subroutine priority unless it also has subroutine priority
Inlined VIs should ignore the Priority setting in VI properties, however an inlined VI dropped in a subroutine priority VI will break the run arrow unless the inlined VI is also set to subroutine priority.
Workaround: Set the inlined subVI to subroutine priority

Reported Version: 2012 Resolved Version: N/A Added: 03/11/2014

Remote Panels181687
ReturnWeb publishing tool fails without error
The web publishing tool may fail to start the web server if the port is already reserved, yet not return an error.
Workaround: Ensure that the port to be used by the web server is not in use.

Reported Version: 8.6 Resolved Version: N/A Added: 08/03/2009

136677
ReturnRemote panels do not work if Internet Explorer is embedded in an ActiveX or .NET Container
If a remote panel is built in LabVIEW 8.6 and embedded in an ActiveX or .NET Container in a LabVIEW 8.6 VI it will not display correctly
Workaround: Use a remote subpanel. This is actually the recommended way to accomplish this task

Reported Version: 8.6 Resolved Version: N/A Added: 10/01/2010

251105
ReturnS&V XControls built as Remote Panel crashes LabVIEW.
Remote panels do not reliably support the Sound and Vibration XControls.
Workaround: Use another mechanism for remote viewing.

Reported Version: 2009 32-bit Resolved Version: N/A Added: 02/18/2011

625718
ReturnThe Web Publishing Tool has incompatibility issues with Internet Explorer 11
When the Web Publishing Tool tries to create a pop-up dialog box or a window, the pop-up dialog box or window will be blocked, and Internet Explorer hosting the Web Publishing Tool may hang or crash. This issue was detected in Internet Explorer 11.
Workaround: On Internet Explorer 11, select Internet options from the Tools menu, switch to the Security tab, remove the checkmark from Enable Protected Mode, and restart Internet Explorer.

Reported Version: 2017 Resolved Version: N/A Added: 05/22/2017

Shared Variables141699
ReturnNI Distributed System Manager does not show deployed libraries if they contain non-Latin characters.
If a library with non-Latin characters (such as Japanese, Chinese, or Korean) is deployed, it will not show up in the NI Distributed System Manager tree view.
Workaround: Rename the library using only the Latin alphabet and re-deploy the library.

Reported Version: 2009 32-bit Resolved Version: N/A Added: 02/10/2009

128059
ReturnShared variable bindings in the same library are not updated properly when copying/renaming the library
If you have shared variables in a library which are bound to I/O servers or other variables that are also in the same library, and you rename or save a copy of the library, the bindings still refer to the original library name.
Workaround: Manually rebind the variables after copying or renaming the library.

Reported Version: 8.0 Resolved Version: N/A Added: 04/28/2009

168005
ReturnDynamic Variable API Does Not Support I/O Servers that Use Ranges
You cannot use the Variable classes, properties, and methods or the associated Shared Variable functions (Dynamic Variable API) to dynamically read and write PSP items published by an I/O Server that uses a Range item. For example, Modbus I/O Servers and Lookout Ranges are affected by this issue.
Workaround: If you want to use the Dynamic Variable API to read or write one of these PSP items, you can create a network-published shared variable and bind it to the PSP item. Then you can use the Dynamic Variable API to read and write the bound shared variable.

Reported Version: 2009 32-bit Resolved Version: N/A Added: 11/10/2009

186808
ReturnShared Variable library on PC is undeployed if the a V in the same project is programmatically deployed to a Real-Time target
When programmatically deploying a VI to a Real-Time target the Shared Variable library residing in the same project as the deployed VI will be undeployed.
Workaround: Programmatically deploy the shared variable library on the PC after deploying the VI to the real-time controller.

Reported Version: 2009 32-bit Resolved Version: N/A Added: 07/20/2011

284289
ReturnSource distributions with block diagrams removed prevents the use of static Shared Variable nodes.
Source distributions that include static Shared Variable nodes with block diagrams removed will return the following error at run-time, 'VI has a bad connection to or cannot find a subVI or external routine.'
Workaround: Use the Programmatic Shared Variable API or do not remove the block diagrams.

Reported Version: 2010 32-bit Resolved Version: N/A Added: 07/20/2011

294285
ReturnType Defined Shared Variable not found in Executable
When a VI is made with the following conditions:
1) Uses a Shared Variable attached to a type definition
2) The type defined control (attached to the shared variable) is not in the main project directory (ie, it is in a different folder)
3) The VI uses dynamic data (or waveform to dynamic data function)
A created executable seems to not include the *.ctl file defining the shared variable type.
This missing type definition causes the run time engine, when starting the executable, to search for and (if the control is not located in the searched directories) fail to find the *.ctl file. If the location of the *.ctl file is specified, the executable runs without issues.
Workaround: Disconnect from Type Def during the build.

Reported Version: 2010 32-bit Resolved Version: N/A Added: 08/02/2011

257735
ReturnClass VIs that call shared variables in a library in an auto-populating folder will not be loaded
If a VI in a class calls a shared variable that is in a library in an auto-populating folder, it will not find the shared variable when the project is loaded
Workaround: Make the folder a snapshot instead of auto-populating and reopen the project

Reported Version: 8.6.1 Resolved Version: N/A Added: 02/01/2013

394454
ReturnData Binding: Path property can change bindings in other VI clones
Writing to a Data Binding: Path can change binding path for other instances of the control if clones of the VI are already open
Workaround: Use programmatic Shared Variable access to update front panel controls instead of Data Binding.

Reported Version: 2012 SP1 Resolved Version: N/A Added: 08/02/2013

458973
ReturnWriting a negative number to single point float Network Shared Variables through the OPC I/O Server fails.
N/A
Workaround: Use Double precision shared variables instead.

Reported Version: 2013 Resolved Version: N/A Added: 03/31/2014

614154
ReturnRenaming a shared variable with a special character in its name (ö/ü/ä/ß) fails when the project is reopened
If you attempt to rename a shared variable that has a special characters in its name, the name will revert to the original name when the project is reopened
Workaround: Do not use special characters in shared variable names

Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017

624802
ReturnSetting binding properties of a control within a preallocated clone subVI or XControl sets the property for all instances of the subVI or XControl
If the BindingPath property is set on a control within a preallocated clone subVI or XControl, all instances of the controls in the subVI or XControl update their BindingPath rather than the one where the property was set
Workaround: Create a unique SubVI or XControl for each instance

Reported Version: 2016 Resolved Version: N/A Added: 05/22/2017

647354
ReturnOpening a new shared variable connection can block reading from other connected variables
When attempting to open a shared variable connection that times out, read operations happening in parallel may stall until the time out occurs.
Workaround: N/A

Reported Version: 2015 SP1 Resolved Version: N/A Added: 01/23/2018

Source Code Control229641
ReturnHang can occur when deploying RT project that has not been check out of VSS
When using VSS source code control for a real time project and trying to deploy code that has not been checked off the deployment window blocks a pop up from VSS saying that the code has not been checked out. The deployment status window is modal so it does not allow you to select to proceed in the VSS window.
Workaround: In the LabVIEW project properties disable the prompts from source code control. Or you could make sure that the VIs are saved prior to deploying.

Reported Version: 2009 32-bit Resolved Version: N/A Added: 07/23/2010

676013
ReturnLVMerge returns error 53 when the VI has a dependency on an XControl
Workaround: N/A

Reported Version: 2017 Resolved Version: N/A Added: 01/23/2018

Toolkit - Report Generation188911
ReturnControl image alignment incorrect when 'new report page' VI is used
When using Append Control Image to Report.vi, the alignment of some images are ignored when New Report Page.vi is used between appended images. This problem only exists with Office 2007. Other versions - Office 2003 and Office 2010 do not exhibit this behavior.
Workaround: Use a New Report Line.vi between appending the image and the New Page.vi

Reported Version: 2009 32-bit Resolved Version: N/A Added: 06/16/2010

Toolkit - Unit Test Framework635510
ReturnAdding a diagram disable structure to a VI can cause the reported code coverage to be 100%
Workaround: N/A

Reported Version: 2015 SP1 Resolved Version: N/A Added: 01/23/2018

Upgrade - Behavior Change51185
47FGSQCS
ReturnCannot save VI as the same name as missing library member VI
If a library contains a VI and the VI is missing, you should be able to save a VI as the same name as the missing VI in order to rebuild the missing VI. Currently, LabVIEW does not allow this.
Workaround: Delete the item from the library, save the new VI as the same name as the missing VI and then move the VI into the library.

Reported Version: 8.5 Resolved Version: N/A Added: 09/01/2007

119444
ReturnMulti-column listbox format lost on upgrade
A Multicolumn listbox created in LV 7.1 may lose its format when opened in LV 8.5 or later. Column headers lose their 3D appearance and font formatting might be lost.
Workaround: Replace the Listbox and recreate all customizations

Reported Version: 8.5 Resolved Version: N/A Added: 07/12/2008

198717
ReturnUnflatten From XML fails for cluster and arrays that consist of variants
Creating a cluster that contains a variant or building an array of variants, and then trying to flatten it to XML using the Flatten To XML VI and then unflattening it using the Unflatten From XML VI will throw error 1106
Workaround: N/A

Reported Version: 2009 32-bit Resolved Version: N/A Added: 02/01/2010

218083
ReturnVIs with errors may show additional errors for code in disabled frames of Conditional Disable Structure
If you have a VI that has errors in it, there may be additional errors shown. The errors will be in code that is inside of a disabled frame of the Conditional Disable Structure (in the 'Default' or 'Windows' frame when on RT).
Workaround: Fix the other errors in the VI, and the additional errors should go away.

Reported Version: 2010 Resolved Version: N/A Added: 07/23/2010

Web Server/Web Services236817
ReturnNI-Auth does not work with Firefox
Web Services using NI-Auth work incorrectly in Firefox. A user's log in credentials will never be accepted.
Workaround: Use Internet Explorer

Reported Version: 2010 32-bit Resolved Version: Unknown Added: 08/03/2010

401078
ReturnOpening any non-VI dialog, such browse for files or one button dialog, may block web service requests from executing.
The most common form of this issue seen when Show Method URL Dialog Box blocks requests to a LabVIEW Web Service. This only affects LabVIEW web services deployed to the debug server or embedded in a LabVIEW executable.
Workaround: Close the dialog box to allow requests to continue

Reported Version: 2013 Resolved Version: N/A Added: 12/01/2014

570102
ReturnCalling the 'Web Server: Server Active' property causes a small memory leak.
Calling the 'Web Server: Server Active' property on any supported platform (including RT) creates a small memory leak.
Workaround: Restart the application to allow the OS to reclaim the memory, or do not call this property often.

Reported Version: 2014 Resolved Version: N/A Added: 08/08/2016

576990
ReturnAssembly created by Web Service Importer from WSDL throws error 1172
In certain cases, it is possible for the Web Service Importer tool in LabVIEW to throw error 1172 when trying to import a WSDL schema.
Workaround: Remove complex data types from the WSDL file.

Reported Version: 2015 Resolved Version: N/A Added: 08/08/2016

599746
ReturnWhen building a web service into an EXE and making an installer, some software dependencies are not automatically selected as additional installers
If you build a web service into an EXE that has method VIs with software dependencies, such as the use of a hardware driver, only VIs with dependencies that are included as Startup VIs for the web service will be automatically selected as additional installers. Any method VI that is not a Startup VI will not have its software dependencies automatically selected.
Workaround: Build the web service into the installer rather than the EXE or manually include the required software dependencies

Reported Version: 2015 SP1 Resolved Version: N/A Added: 05/22/2017

688771
ReturnCannot add CA-signed certificates to LabVIEW Web Services
LabVIEW Web Services only accept certificates created by the LabVIEW API. Valid certificates will not appear as options to add to web services pushing design decisions to use LabVIEW certificates, even when not the best solution.
Workaround: Create a certificate with an identical name of the key for the signed certificate. Install the certificate selecting your root CA certificate. Create a new virtual host with the previously made certificate. Replace the LabVIEW generated private key with your correct private key in certstore.

Reported Version: 2017 SP1 Resolved Version: N/A Added: 03/12/2018